Purpose: Three-dimensional in-vivo dose verification is one of the standing challenges in radiation therapy. X-ray-induced acoustic tomography has recently been proposed as an imaging method for use in in-vivo dosimetry. The aim of this study was to investigate the accuracy of reconstructing three-dimensional (3D) absolute dose using x-ray-induced acoustic tomography. We performed this investigation using two different tomographic dose reconstruction techniques.

Methods: Two examples of 3D dose reconstruction techniques for x-ray acoustic imaging are investigated. Dose distributions are calculated for varying field sizes using a clinical treatment planning system. The induced acoustic pressure waves which are generated by the increase in temperature due to the absorption of pulsed MV x-rays are simulated using an advanced numerical modeling package for acoustic wave propagation in the time domain. Two imaging techniques, back projection and iterative time reversal, are used to reconstruct the 3D dose distribution in a water phantom with open fields. Image analysis is performed and reconstructed depth dose curves from x-ray acoustic imaging are compared to the depth dose curves calculated from the treatment planning system. Calculated field sizes from the reconstructed dose profiles by back projection and time reversal are compared to the planned field size to determine their accuracy. The iterative time reversal imaging technique is also used to reconstruct dose in an example clinical dose distribution. Image analysis of this clinical test case is performed using the gamma passing rate. In addition, gamma passing rates are used to validate the stopping criteria in the iterative time reversal method.

Results: Water phantom simulations showed that back projection does not adequately reconstruct the shape and intensity of the depth dose. When compared to the depth of maximum dose calculated by a treatment planning system, the maximum dose depth by back projection is shifted deeper by 55 and 75 mm for 4 × 4 cm and 10 × 10 cm field sizes, respectively. The reconstructed depth dose by iterative time reversal accurately agrees with the planned depth dose for a 4 × 4 cm field size and is shifted deeper by 12 mm for the 10 × 10 cm field size. When reconstructing field sizes, the back projection method leads to 18% and 35% larger sizes for the 4 × 4 cm and 10 × 10 cm fields, respectively, whereas the iterative time reversal method reconstructs both field sizes with < 2% error. For the clinical dose distribution, we were able to reconstruct the dose delivered by a 1 degree sub-arc with a good accuracy. The reconstructed and planned doses were compared using gamma analysis, with> 96% gamma passing rate at 3%/2 mm.

Conclusions: Our results show that the 3D x-ray acoustic reconstructed dose by iterative time reversal is considerably more accurate than the dose reconstructed by back projection. Iterative time reversal imaging has a potential for use in 3D absolute dosimetry.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.13961DOI Listing

Publication Analysis

Top Keywords

time reversal
32
iterative time
28
field sizes
20
depth dose
20
dose
18
x-ray-induced acoustic
12
acoustic imaging
12
x-ray acoustic
12
treatment planning
12
planning system
12

Similar Publications

Stoma reversal surgery is known for relatively high complication rates. While Enhanced Recovery After Surgery (ERAS) protocols are extensively validated for colorectal surgery, their use in stoma reversal remains underexplored. This systematic review and meta-analysis evaluates clinical outcomes of stoma reversal surgery under ERAS protocols compared to standard care (SC) practices.

View Article and Find Full Text PDF

Aim: Periodontitis is a chronic inflammatory disease initiated by dysbiosis of the local microbial community. As a non-specific phosphodiesterase inhibitor, dipyridamole features anti-oxidant and anti-inflammatory properties. This study aimed to investigate the effects of dipyridamole in an experimental rat model of periodontitis.

View Article and Find Full Text PDF

Advancement in synthetic gene circuits engineering: An alternative strategy for microRNA imaging and disease theranostics.

Biotechnol Adv

January 2025

Department of Urology, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710004, China; Institute of Medical Engineering, School of Basic Medical Sciences, Xi'an Jiaotong University, Xi'an 710061, China; Xianyang Key Laboratory of Molecular Imaging and Drug Synthesis, School of Pharmacy, Shaanxi University of International Trade & Commerce, Xianyang 712046, China. Electronic address:

Gene circuits, which are genetically engineered systems designed to regulate gene expression, are emerging as powerful tools in disease theranostics, especially in mammalian cells. This review explores the latest advances in the design and application of gene circuits for detecting and treating various diseases. Synthetic gene circuits, inspired by electronic systems, offer precise control over therapeutic gene activity, allowing for real-time, user-defined responses to pathological signals.

View Article and Find Full Text PDF

Polysaccharides from maggot extracts suppress colorectal cancer progression by inducing ferroptosis via HMOX1/GPX4 signaling pathway.

Int J Biol Macromol

January 2025

the Affiliated Cancer Hospital of Nanjing Medical University and Jiangsu Cancer Hospital and Jiangsu Institute of Cancer Research, Nanjing 210009, China; Jiangsu Key Laboratory of Molecular and Translational Cancer Research, 42 Baiziting Road, Xuanwu District, Nanjing 210009, China. Electronic address:

Maggots contain various kinds of polysaccharides and recent studies mostly concentrated on their anti-inflammatory functions. While the molecule mechanisms related to the polysaccharides inhibiting carcinogenesis remains unclear. Here we characterized the polysaccharides extracted from maggot (MEs) determining their anti-colon cancer potentials.

View Article and Find Full Text PDF

Introduction: Reversible cerebral vasoconstriction syndrome (RCVS) is thought to be benign by nature, but a proportion of patients still suffer from neurological deficits on follow-up.

Objective: To understand what factors may influence a patient's recovery from RCVS.

Methods: The Clinical Research Data Warehouse at this institution was employed to search the medical records for patients with diagnosis and treatment of RCVS (2010-2021).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!