A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Direct nano-electrospray ionization tandem mass spectrometry for the quantification and identification of metronidazole in its dosage form and human urine. | LitMetric

A rapid, sensitive and direct nano-electrospray ionization-tandem mass spectrometry (NS-ESI-MS/MS) method, using an offline nanospray (NS) capillary, has been developed and validated for the analysis of metronidazole (MTZ). A mixture of 2 µl MTZ sample solution prepared in an ionization solvent consisting of methanol : water : formic acid in a ratio of 80 : 20 : 0.3, together with 2 µl of an internal standard (IS), 1,3,6-polytyrosine, is loaded into the back of the NS capillary. The NS capillary was fitted into the ion source at a distance of 3 mm between the NS tip and MS orifice. The sample is then analysed and acquired a sustainable signal that allowed for data compilation across various data points for MTZ identification and quantification. The quantification relied on the ratio of the [M + H] peaks of MTZ and IS with values of 172.0717 and 182.0812, respectively, while the identification relied on the MS/MS of the precursor ions [M + H] of both compounds and their fragments at 128.05 for MTZ and 165.1 and 136.07 for the IS. The NS-ESI-MS/MS method was accurate and precise for the quantification of MTZ over the concentration range from 2.5 to 25 000 ng ml. The applicability of the method was confirmed by MTZ analysis in its pharmaceutical dosage form and detection of the analyte in clinical human urine samples without any sample treatment procedure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6894584PMC
http://dx.doi.org/10.1098/rsos.191336DOI Listing

Publication Analysis

Top Keywords

direct nano-electrospray
8
mass spectrometry
8
dosage form
8
human urine
8
ns-esi-ms/ms method
8
mtz
7
nano-electrospray ionization
4
ionization tandem
4
tandem mass
4
quantification
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!