Cardiac-related diseases are still the number one cause of death worldwide. Methods and technologies to suppress this problem are currently being investigated by integrating electrocardiographic (ECG) monitoring with other sensing modalities in order to detect these diseases more accurately and in due course of time. In this paper, we propose a battery-less and flexible device to be worn as a chest patch for monitoring cardiac and hemodynamic parameters through electrical and acoustic measurements, combined with sweat pH level estimation and skin temperature, by swiping a smartphone over the patch area for enough time (≃5 seconds) to allow adequate acquisition and estimation of the aforementioned parameters. Fast screening of vital signals from patients in ambulatory or emergency scenarios can thus be achieved by this Near Field Communication (NFC) powered device, as well as home or office monitoring for those individuals suffering from diseases affecting the hemodynamic, cardiac and endocrine parameters detected by the proposed technology. Current consumption of the device is 1 mA for harvested levels of 1.8 V, yielding a power requirement of 1.8 mW. Within these conditions, the sensitivities achieved by each sensing modality are 42 mV/unit for pH, 0.12 °C for temperature, 48 dB SNR for ECG and -56 dBA for acoustic measurements.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBCAS.2019.2956810DOI Listing

Publication Analysis

Top Keywords

chest patch
8
cardiac hemodynamic
8
endocrine parameters
8
acoustic measurements
8
nfc-powered flexible
4
flexible chest
4
patch fast
4
fast assessment
4
assessment cardiac
4
hemodynamic endocrine
4

Similar Publications

Objective: The study aims to systematically characterize the effect of CT parameter variations on images and lung radiomic and deep features, and to evaluate the ability of different image harmonization methods to mitigate the observed variations.

Approach: A retrospective in-house sinogram dataset of 100 low-dose chest CT scans was reconstructed by varying radiation dose (100%, 25%, 10%) and reconstruction kernels (smooth, medium, sharp). A set of image processing, convolutional neural network (CNNs), and generative adversarial network-based (GANs) methods were trained to harmonize all image conditions to a reference condition (100% dose, medium kernel).

View Article and Find Full Text PDF

Accuracy of Rhythm Diagnostic Systems' MultiSense in Detection of Arterial Oxygen Saturation and Respiratory Rate During Hypoxia in Humans: Effects of Skin Color and Device Localization.

Sensors (Basel)

December 2024

Biomedicine Research Center of Strasbourg (CRBS), UR 3072, "Mitochondria, Oxidative Stress and Muscle Plasticity", Faculty of Medicine, University of Strasbourg, 67000 Strasbourg, France.

The continuous monitoring of oxygen saturation (SpO) and respiratory rates (RRs) are major clinical issues in many cardio-respiratory diseases and have been of tremendous importance during the COVID-19 pandemic. The early detection of hypoxemia was crucial since it precedes significant complications, and SpO follow-up allowed early hospital discharge in patients needing oxygen therapy. Nevertheless, fingertip devices showed some practical limitations.

View Article and Find Full Text PDF

Endometriosis presenting as catamenial pneumothorax, pneumopericardium and pneumoperitoneum.

BMJ Case Rep

January 2025

Pulmonary Medicine, K S Hegde Medical Academy, Mangaluru, Karnataka, India

A nulliparous woman in her late 30s with a history of pericardial patch repair for atrial septal defect and completed treatment for pulmonary tuberculosis 9 years ago presented with chest pain, breathlessness and abdominal pain. Radiological imaging revealed right-sided pneumothorax, pneumopericardium and pneumoperitoneum for which an intercostal drain (ICD) was placed. A contrast-enhanced CT of the abdomen showed a distal stomach perforation, which was managed conservatively.

View Article and Find Full Text PDF

Immunoglobulin G4-related disease (IgG4-RD) is an immune-mediated chronic fibro-inflammatory condition, that can involve multiple systems. Immunoglobulin G4-related respiratory disease (IgG4-RRD) is relatively rare, with non-specific clinical symptoms. Hemoptysis is a rare clinical symptom of IgG4-RRD, and cases of massive hemoptysis in adults have not been reported.

View Article and Find Full Text PDF

Biological drugs are extensively used to treat various inflammatory diseases, including psoriasis, atopic dermatitis (AD), and rheumatoid arthritis. While generally effective and safe, these therapies have been increasingly associated with secondary development of vitiligo, especially with anti-TNF α and anti-IL17 drugs. Dupilumab, an IL-4 receptor alpha antagonist used in moderate to severe AD, rarely induces vitiligo.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!