Electronic textiles featuring a controllable strain sensing capability and comfortable wearability have attracted huge interests with the rapid development of wearable strain sensor systems. It is still a great challenge to simultaneously achieve a strain sensor with low cost, biocompatibility, large-area compatibility, and excellent sensing performances. Here, two kinds of cotton fabric-based strain sensors (CFSSs) with different conductive network structures are prepared, i.e., CFSS-90° and CFSS-45° (90° and 45° represent the angles between intertwined direction in cotton yarns and the stretching direction in tension). After multiple dipping processes, graphene nanosheets are deposited onto cotton fabrics, and then, the fabrics are encapsulated by polydimethylsiloxane (PDMS). Morphology analyses reveal that an interpenetrating structure is generated between cotton fabric and PDMS. The strength and elongation at break of CFSS-45° are about 4.5 MPa and 75% strain, which are higher than the counterparts of CFSS-90° (1.75 MPa and 30% strain, respectively). In a uniaxial stretching test, the two strain sensors exhibit excellent linear current-voltage behavior and fast response time (∼90 ms). During the cyclic stretching-releasing test, CFSSs present remarkable reproducibility, durability (10 000 cycles at 30% strain for CFSS-45°), and a sensing capability for detecting very low strain (∼0.4% strain).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acsami.9b17173 | DOI Listing |
ACS Appl Mater Interfaces
January 2025
Materials Science and Technology Division, CSIR-National Institute for Interdisciplinary Science and Technology, Trivandrum 695 019, Kerala, India.
Lightweight flexible piezoelectric devices have garnered significant interest over the past few decades due to their applications as energy harvesters and wearable sensors. Among different piezoelectrically active polymers, poly(vinylidene fluoride) and its copolymers have attracted considerable attention for energy conversion due to their high flexibility, thermal stability, and biocompatibility. However, the orientation of polymer chains for self-poling under mild conditions is still a challenging task.
View Article and Find Full Text PDFJ Biomech Eng
January 2025
State Key Laboratory of Fluid Power and Mechatronic Systems, Department of Mechanical Engineering, Zhejiang University, Hangzhou, 315000, China.
Due to individual differences, accurate identification of tissue elastic parameters is essential for biomechanical modeling in surgical guidance for hepatic venous injections. This paper aims to acquire the absolute Young's modulus of heterogeneous soft tissues during endoscopic surgery with 2D ultrasound images. First, we introduced a force-sensor-less approach that utilizes a pre-calibrated soft patch with a known Young's modulus and its ultrasound images to calculate the external forces exerted by the probe on the tissue.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Hebei Provincial Key Laboratory of Photoelectric Control on Surface and Interface, and College of Science, Hebei University of Science and Technology, Yuxiang Road 26, Shijiazhuang 050080, PR China.
The development of silk fibroin-based hydrogels with excellent biocompatibility, aqueous processability, and facile controllability in structure is indeed an exciting advancement for biological research and strain sensor applications. However, silk fibroin-based hydrogel strain sensors that combine high conductivity, high stretchability, reusability, and high selectivity are still desired. Herein, we report a simple method for preparing double-network hydrogels including silk fibroin and poly(acrylic acid) sodium-polyacrylate (PAA-PAAS) networks.
View Article and Find Full Text PDFSci Rep
January 2025
College of Geosciences and Engineering, North China University of Water Resources and Electric Power, Zhengzhou, 450046, China.
The failure of locked-segment landslides is associated with the destruction of locked segments that exhibit an energy accumulation effect. Thus, understanding their failure mode and instability mechanism for landslide hazard prevention and control is critical. In this paper, multiple instruments, such as tilt sensors, pore water pressure gauges, moisture sensors, matrix suction sensors, resistance strain gauges, miniature earth pressure sensors, a three-dimensional (3D) laser scanner, and a camera, were used to conduct the physical model tests on the rainfall-induced arch locked-segment landslide to analyze the resulting tilting deformation and evolution mechanism.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00, Brno, Czech Republic.
Antibiotic-resistant strains of Staphylococcus aureus pose a significant threat in healthcare, demanding urgent therapeutic solutions. Combining bacteriophages with conventional antibiotics, an innovative approach termed phage-antibiotic synergy, presents a promising treatment avenue. However, to enable new treatment strategies, there is a pressing need for methods to assess their efficacy reliably and rapidly.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!