The purpose of the study was to determine the influence of initial conditions of a microclimate on volunteers' permissible exposure limits to a hot and humid environment. Eighteen experimental studies with the participation of three volunteers were performed under controlled microclimate conditions (two climate chambers). The skin temperature and body core temperature were measured after they had stabilized in the following microclimate conditions: temperature of 17, 21 and 23 °C, relative humidity of 50% and hot microclimate conditions, i.e., temperature of 35 and 42 °C, humidity of 80% and physical work load at 30 W. The time needed to reach a body core temperature of 38 °C was determined under hot conditions. Heat accumulation was calculated. Lowering volunteers' skin temperature under conditions of stabilized physiological parameters prolongs the time necessary for the body core temperature to reach 38 °C during physical work in a hot and humid environment. Appropriate acclimatization before exposure may prolong the time of safe work in a hot environment, e.g., during activities of rescue services.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10803548.2019.1701305DOI Listing

Publication Analysis

Top Keywords

skin temperature
12
microclimate conditions
12
body core
12
core temperature
12
temperature °c
12
temperature
8
time safe
8
hot environment
8
hot humid
8
humid environment
8

Similar Publications

Perioperative hypothermia is a frequent clinical complication resulting from the cold environment of the operating room and prolonged skin exposure, leading to adverse outcomes and increased healthcare burdens. To address this issue, this narrative review discusses in detail the currently common warming strategies for perioperative hypothermia .Forced air warming (FAW) systems are widely recognized as the most effective intervention for maintaining core body temperature.

View Article and Find Full Text PDF

Explicit metrics for implicit emotions: investigating physiological and gaze indices of learner emotions.

Front Psychol

December 2024

Departent of Learning, Data-Analytics and Technology, Faculty of Behavioural, Management and Social Sciences, University of Twente, Enschede, Netherlands.

Learning experiences are intertwined with emotions, which in turn have a significant effect on learning outcomes. Therefore, digital learning environments can benefit from taking the emotional state of the learner into account. To do so, the first step is real-time emotion detection which is made possible by sensors that can continuously collect physiological and eye-tracking data.

View Article and Find Full Text PDF

Objective: Researchers have proposed a novel surgical treatment for moderate diabetic foot ulcer: tibial periosteal distraction (TPD) which could improve affected limb microcirculation. We aimed to describe the method and therapeutic effects of this technique.

Methods: We provided a technical guide to perform TPD surgery for the treatment of moderate diabetic foot ulcer of who had been treated in our department.

View Article and Find Full Text PDF

Managing wounds infected with multi-drug-resistant (MDR) bacteria remains a significant public health challenge in clinical settings. While multifunctional hydrogels are commonly employed to treat skin infections, there is a scarcity of hydrogels that effectively combine cationic guar gum (CG) with both potent antimicrobial and safe therapeutic actions. This study introduces a novel pH responsive, dual-dynamically crosslinked hydrogel (CFC-PDA/Ag), synthesized by crosslinking CG with polydopamine (PDA)-coated silver nanozymes (PDA/PM-AgNPs).

View Article and Find Full Text PDF

Microtextured microneedles are tiny needle-like structures with micron-scale microtextures, and the drugs stored in the microtextures can be released after entering the skin to achieve the effect of precise drug delivery. In this study, the skin substitution model of Ogden's hyperelastic model and the microneedle array and microtexture models with different geometrical parameters were selected to simulate and analyse the flow of the microtexture microneedle arrays penetrating the skin by the finite-element method, and the length of the microneedles was determined to be 200 μm, the width 160 μm, and the value of the gaps was determined to be 420 μm. A four-pronged cone was chosen as the shape of microneedles, and a rectangle was chosen as the shape of the drug-carrying microneedle.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!