Influence of Hyrax screw position on dental movement and cortical bone: A study of finite elements.

J Clin Exp Dent

Ph.D in Epidemiology; Biomedical Stomatology Group, Universidad de Antioquia, Medellín, Colombia. Department of Periodontology, School of Dentistry, Universidad de Antioquia.

Published: December 2019

Background: Rapid maxillary expansion (RME) has effects on the dental and periodontal structures of the parts involved, which vary according to the design and position of the expansion screw. The purpose of the study was to determine the optimal three-dimensional position of the Hyrax screw to obtain precise control of the dental movement and effect on the bone cortex using the finite element method (FEM).

Material And Methods: RME was performed from the patient whom two Cone-Beam computerized tomography scans (CBCT) were obtained: T1 before expansion, and T2 three months after stabilization of RME. The FEM model was designed with T1 and of Hyrax photographs. FEM was obtained by comparing the simulation, T2, and clinical results. Three sagittal screw positions (anterior-middle-posterior) and vertical (upper-medium-low) were evaluated.

Results: A coronal- buccal displacement of premolars and first molars was found which decreased in the occlusal-apical direction, presenting different types of dental movement in the screw positions; besides, a tendency of translational movement in the posterior-high location was observed. In the posterior-high position a higher concentration of efforts and homogeneous deformations in the periodontal ligament and vestibular cortex of the cervical area of first molars, first and second premolars were observed, with variations according to the screw position and the distribution of stresses.

Conclusions: The ideal location of the expansion screw for controlling dental movement and periodontal side effects was the high-posterior position. Maxillary expansion, dental movement, finite element analysis, orthodontic appliances.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6894920PMC
http://dx.doi.org/10.4317/jced.56347DOI Listing

Publication Analysis

Top Keywords

dental movement
20
hyrax screw
8
screw position
8
maxillary expansion
8
expansion screw
8
finite element
8
screw positions
8
screw
7
position
6
dental
6

Similar Publications

Imaging Retrospective Study Regarding the Variability of the Osseous Landmarks for IAN Block.

J Clin Med

January 2025

Department of Anesthesiology and Oral Surgery, Multidisciplinary Center for Research, Evaluation, Diagnosis and Therapies in Oral Medicine, "Victor Babes" University of Medicine and Pharmacy, Eftimie Murgu Sq. No. 2, 300041 Timisoara, Romania.

: The aim of this study is to identify the most accurate and consistent landmarks for determining the precise location of the mandibular foramen (MF) and the mandibular ramus, suggesting appropriate adjustments to anesthesia techniques based on these variations in order to improve the success rate of the inferior alveolar nerve (IAN) block. : CT scans of the mandibles from 100 patients were analyzed to measure the distance between the MF and various landmarks, including the sigmoid notch, gonion, posterior and anterior margins of the ramus, temporal crest, and the mandibular ramus height from the condyle to the gonion. The width of the mandibular ramus was also assessed, with correlations made to age and gender.

View Article and Find Full Text PDF

Objective: To evaluate the clinical efficacy of clear aligner therapy in patients with severe periodontitis accompanied by pathological tooth displacement in the anterior region.

Methods: This retrospective study analyzed patients diagnosed with severe periodontitis and pathological displacement in the anterior region, who visited both the Periodontics and Orthodontics Departments at Peking University School and Hospital of Stomatology between 2019 and 2022. A total of 26 eligible cases were included in this study.

View Article and Find Full Text PDF

Introduction: Using digital technology, respectively the use of intraoral scanners has increased exponentially in recent years. Intraoral scanners have gained traction and widespread use in the field of dental prosthetics and orthodontics. While the use of these digital devices enables the detection of visible areas of error in order to allow clinicians to correct those areas immediately without a need of restarting the entire process from the beginning as it should be done in the conventional method and subsequent procedures.

View Article and Find Full Text PDF

: Dental pulp and its neuro-vascular bundle (NVB) are among the least studied dental tissues. This study identified the best method for evaluating ischemic risks in the dental pulp and NVB of healthy lower premolars under orthodontic forces and in intact periodontium. : Nine 3D models of the second lower premolar were reconstructed based on the CBCT scans from nine patients.

View Article and Find Full Text PDF

The present article describes a step-by-step maximally digitalized workflow protocol with computer-aided design and computer-aided manufacturing (CAD/CAM) in partial-arch edentulous patients rehabilitated with fixed dental prostheses and removable partial dentures (FDPs and RPDs). Facial digitalization, intraoral scans, and functional mandibular movement recordings were used to create a 4D virtual patient on commercially available CAD software. The fixed components including post-and-cores, both metal-ceramic with extra-coronal attachment and monolithic zirconia crowns, and the RPDs were manufactured by computer numerical controlled direct milling.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!