Multiple published studies involving computed tomographic (CT) examinations of the equine head utilise a wide range of mAs parameters for image acquisition. This prospective, experimental study assessed the effects of lowering mAs during CT image acquisition on image quality and scatter radiation on 10 cadaver equine heads. Each head was scanned three times at 300, 225, and 150 mAs, with all other scanning parameters remaining constant between series. An anthropomorphic phantom was positioned adjacent to each equine head during image acquisition, mimicking a human bystander, with an ionization chamber attached to the phantom at eye level. Each series was reconstructed using filtered back projection, using medium (H30) and high (H80) frequency reconstruction algorithms. Quantitative image quality assessment was performed by calculating signal to noise ratio (SNR) and contrast to noise ratio (CNR). Two qualitative image quality assessments were performed independently by three blinded board certified veterinary radiologists with a 4 week interval, using a visual grade analysis model adapted from peer reviewed medical literature. Ionization chamber measurements, calculated volume CT dose index (CTDIvol), and dose-length product (DLP) were recorded. Halving radiation dose during image acquisition from 300 to 150mAs resulted in comparable image quality between series. There was a statistically significant and linear relationship between mAs and scatter radiation to the bystander; halving mAs during image acquisition resulted in halving of scatter radiation. Results of this cadaveric study support the use of lower mAs settings during standing CT examinations of the equine head.

Download full-text PDF

Source
http://dx.doi.org/10.1111/vru.12823DOI Listing

Publication Analysis

Top Keywords

image quality
20
image acquisition
20
equine head
16
scatter radiation
12
image
10
radiation dose
8
examinations equine
8
mas image
8
ionization chamber
8
noise ratio
8

Similar Publications

Objective: To evaluate the postoperative complications and prognosis of renal cell carcinoma (RCC) in a solitary kidney after irreversible electroporation (IRE).

Materials And Methods: A total of 8 patients with 9 RCCs in a solitary kidney treated with computed tomography (CT)-guided IRE from February 2017 to September 2020 were retrospectively analyzed. Follow-up included contrast-enhanced CT or magnetic resonance imaging examinations at 1 day, 1 week, 1 month, 3 months, 6 months, 12 months, and each year after IRE and the evaluation of the incidence of postoperative complications, renal function changes, local tumor recurrence, and metastasis.

View Article and Find Full Text PDF

Importance: Data characterizing the severity and changing prevalence of bone mineral density (BMD) deficits and associated nonfracture consequences among childhood cancer survivors decades after treatment are lacking.

Objective: To evaluate risk for moderate and severe BMD deficits in survivors and to identify long-term consequences of BMD deficits.

Design, Setting, And Participants: This cohort study used cross-sectional and longitudinal data from the St Jude Lifetime (SJLIFE) cohort, a retrospectively constructed cohort with prospective follow-up.

View Article and Find Full Text PDF

Assessing the efficiency of pixel-based and object-based image classification using deep learning in an agricultural Mediterranean plain.

Environ Monit Assess

January 2025

Department of Landscape Architecture, Remote Sensing and GIS Laboratory, University of Cukurova, Adana, 01330, Turkey.

Recent advancements in satellite technology have greatly expanded data acquisition capabilities, making satellite imagery more accessible. Despite these strides, unlocking the full potential of satellite images necessitates efficient interpretation. Image classification, a widely adopted for extracting valuable information, has seen a surge in the application of deep learning methodologies due to their effectiveness.

View Article and Find Full Text PDF

Harmonized technical standard test methods for quality evaluation of medical fluorescence endoscopic imaging systems.

Vis Comput Ind Biomed Art

January 2025

School of Engineering Medicine and School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China.

Fluorescence endoscopy technology utilizes a light source of a specific wavelength to excite the fluorescence signals of biological tissues. This capability is extremely valuable for the early detection and precise diagnosis of pathological changes. Identifying a suitable experimental approach and metric for objectively and quantitatively assessing the imaging quality of fluorescence endoscopy is imperative to enhance the image evaluation criteria of fluorescence imaging technology.

View Article and Find Full Text PDF

Due to incessant contamination of the groundwater system near the dumpsite in southwestern Nigeria Basement Complex, this study seeks to evaluate the impact of the Odogbo dumpsite on the local groundwater system by integrating geophysical and geochemical methodologies. Aeromagnetic data covering the study area was acquired, processed, and enhanced to delineate basement features that could potentially be passing plumes to the groundwater system. Concurrently, geoelectric methods using 2-D dipole-dipole imaging and vertical electrical sounding (VES) were utilized to characterize the vulnerability indices of the lithologies underlying the dumpsite.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!