A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Multicentre study on the consistency of PD-L1 immunohistochemistry as predictive test for immunotherapy in non-small cell lung cancer. | LitMetric

Aims: Investigate the impact of interlaboratory- and interobserver variability of immunohistochemistry on the assessment of programmed death ligand 1 (PD-L1) in non-small cell lung cancer (NSCLC).

Methods: Two tissue microarrays (TMAs) were constructed from 50 (TMA-A) and 51 (TMA-B) resected NSCLC cases, and distributed among eight centres. Immunostaining for PD-L1 was performed using Agilent's 22C3 pharmDx Assay (pharmDx) and/or a 22C3 laboratory developed test (LDT). The interlaboratory variability of staining- and interobserver variability of scoring for PD-L1 were assessed in selected critical samples (samples at the cut-off of positivity) and non-critical samples. Also, PD-L1 epitope deterioration in time in stored unstained slides was analysed. Krippendorff's alpha values (0=maximal, 1=no variability) were calculated as measure for variability.

Results: For interlaboratory variability of immunostaining, the percentage of PD-L1 positive cases among centres ranged 40%-51% (1% cut-off) and 23%-30% (50% cut-off). Alpha values at 1% cut-off were 0.88 (pharmDx) and 0.87 (LDT) and at 50% cut-off 0.82 (pharmDx) and 0.95 (LDT). Interobserver variability of scoring resulted in PD-L1 positive cases ranging 29%-55% (1% cut-off) and 14%-30% (50% cut-off) among pathologists. Alpha values were at 1% cut-off 0.83 (TMA-A) and 0.66 (TMA-B), and at 50% cut-off 0.77 (TMA-A) and 0.78 (TMA-B). Interlaboratory variability of staining was higher (p<0.001) in critical samples than in non-critical samples at 50% cut-off. Furthermore, PD-L1 epitope deterioration in unstained slides was observed after 12 weeks.

Conclusions: The results provide insight in factors contributing to variability of immunohistochemical assessment of PD-L1, and contribute to more reliable predictive testing for PD-L1.

Download full-text PDF

Source
http://dx.doi.org/10.1136/jclinpath-2019-205993DOI Listing

Publication Analysis

Top Keywords

50% cut-off
16
interobserver variability
12
interlaboratory variability
12
alpha values
12
cut-off
9
non-small cell
8
cell lung
8
lung cancer
8
variability scoring
8
scoring pd-l1
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!