ACTIVE MIDDLE EAR VIBRANT SOUNDBRIDGE SOUND IMPLANT.

Acta Clin Croat

Department of Otorhinolaryngology and Head and Neck Surgery, Sestre milosrdnice University Hospital Centre, School of Medicine, University of Zagreb, Zagreb, Croatia.

Published: June 2019

The Vibrant Soundbridge represents a new approach to hearing improvement in the form of active implantable middle ear hearing device. Unlike conventional acoustic hearing aids, which increase the volume of sound that goes to the eardrum, the Vibrant Soundbridge bypasses the ear canal and eardrum by directly vibrating the small bones in the middle ear. Because of its design, no portion of the device is placed in the ear canal itself. The Vibrant Soundbridge has been approved by the FDA as a safe and effective treatment option for adults with moderate to severe sensorineural, conductive or mixed hearing losses who desire an alternative to the acoustic hearing aids, for better hearing. The paper presents a review of the active middle ear implant Vibrant Soundbridge, which has been also implanted at the Department of Otorhinolaryngology and Head and Neck Surgery, Sestre milosrdnice University Hospital Center, which is the Referral Center for Cochlear Implantation and Surgery of Hearing Impairment and Deafness of the Ministry of Health, Republic of Croatia.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6884373PMC
http://dx.doi.org/10.20471/acc.2019.58.02.20DOI Listing

Publication Analysis

Top Keywords

vibrant soundbridge
20
middle ear
16
active middle
8
implant vibrant
8
acoustic hearing
8
hearing aids
8
ear canal
8
hearing
7
ear
6
vibrant
5

Similar Publications

Background: The "floating mass transducer" (FMT) of the Vibrant Soundbridge was initially attached to the long process of the incus (LP). In patients missing an incus, coupling to the stapes head using the Vibroplasty CliP-coupler is used. Its main limitation is the height, leading to potential contact with the tympanic membrane.

View Article and Find Full Text PDF

Long-term safety and subjective satisfaction of Bonebridge and Vibrant Soundbridge in congenital unilateral conductive hearing loss.

Acta Otorhinolaryngol Ital

October 2024

Department of Otolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Ministry of Education Key Laboratory of Otolaryngology Head and Neck Surgery, Capital Medical University, Beijing, China.

Purpose: The objective of this study was to assess and compare the long-term safety and subjective satisfaction levels of Bonebridge (BB) and Vibrant Soundbridge (VSB) in patients with congenital unilateral conductive hearing loss (UCHL).

Methods: The hearing effectiveness was measured using sound field hearing threshold (SFHT) and word recognition score (WRS). Long-term safety and subjective satisfaction levels were measured by questionnaires, including Speech, Spatial, and Qualities of Hearing Scale-12 (SSQ-12) and Abbreviated Profile of Hearing Aid Benefit (APHAB).

View Article and Find Full Text PDF

Outcomes of Active Middle Ear Implants: Speech Perception and Quality of Life.

J Pers Med

August 2024

King Abdullah Ear Specialist Center (KAESC), College of Medicine, King Saud University Medical City, King Saud University, Riyadh 11481, Saudi Arabia.

Objective: To evaluate audiological outcomes, quality of life, and complications in patients implanted with Active middle ear implants (AMEI). The secondary objective is to investigate the required duration after implantation to reach satisfactory outcomes.

Methods: This retrospective study included 31 patients implanted with Active middle ear implants (AMEI) with different methods of floating mass transducer attachment.

View Article and Find Full Text PDF

Background: Middle ear active implants, such as the Vibrant Soundbridge (VSB), offer an alternative to reconstructive surgery and other implantable hearing aid systems for patients with conductive, mixed, or sensorineural hearing loss. The primary objective of this work is to describe the auditory results obtained with VSB in our patient cohort, measuring the auditory gain in terms of average tonal thresholds and spoken word discrimination at 65 dB. Secondly, auditory gain differences between different types of hearing loss, coupling to the ossicular chain compared to round and oval windows, and the impact of open versus more conservative surgical approaches, were analyzed.

View Article and Find Full Text PDF

Objective: The goal of the study was to determine the short- and long-term outcome of health-related quality of life (HRQoL) in adults implanted with a Vibrant Soundbridge (VSB).

Methods: Twenty-one adults (8 females, 13 males; mean age at implantation: 57 ±10 years) who received a unilateral VSB for combined or conductive hearing loss, were administered two questionnaires: the Nijmegen Cochlear Implant Questionnaire (NCIQ) as a measure of hearing-specific HRQoL, and the Health Utility Index 3 (HUI 3) as a measure of generic HRQoL. The questionnaires were administered before implantation and three, six, 12 and 24 months after processor activation.

View Article and Find Full Text PDF