SiO/SiC coatings were deposited onto ceramics disks using plasma enhanced chemical vapor deposition. The effects of deposition pressure and gas-flow ratio on the refractive index, extinction coefficient, and SiC composition were studied. For the highest studied SiH to CH gas-flow ratio of 1.5, the refractive index increased by 17% from 2.53 (at the wavelength of 845 nm) to 2.96 (at the wavelength of 400 nm). For the lowest studied SiH to CH gas-flow ratio of 0.5, the refractive index only increased by 4% from 2.11 (at the wavelength of 845 nm) to 2.20 (at the wavelength of 400 nm). At higher deposition pressures, the variation in refractive index of the SiC coatings was significantly lower showing a slight increase from 1.93 (at a wavelength of 845 nm) to 1.96 at a wavelength of 400 nm. Except for the case of a low SiH to CH gas-flow ratio of 0.5, for light with wavelengths ≤ 650 nm, the extinction coefficient of the SiC coatings increased significantly. Light with a wavelength > 650 nm had an extinction coefficient near 0 in all cases. After annealing the sample at 400°C for 4 hours, hydrogen-related bonds broke and the stress of the film was reduced from -245 to -71 MPa. By utilizing different thicknesses of SiC, the full standard dental shade guide was matched with the ΔE of each coated disk being less than 3.3 compared to the shade guide.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6901346PMC
http://dx.doi.org/10.1111/jace.16525DOI Listing

Publication Analysis

Top Keywords

gas-flow ratio
16
ratio refractive
12
extinction coefficient
12
sih gas-flow
12
wavelength 845
12
wavelength 400
12
coefficient sic
8
studied sih
8
refractive increased
8
sic coatings
8

Similar Publications

This study explores the low-temperature synthesis of graphene using plasma-enhanced chemical vapor deposition (PECVD), emphasizing the optimization of process parameters to achieve controlled growth of pristine and hydrogenated graphene. Graphene films were synthesized at temperatures ranging from 700 °C to as low as 400 °C by varying methane (25-100 sccm) and hydrogen (25-100 sccm) gas flow rates under 10-20 mBar pressures. Raman spectroscopy revealed structural transitions: pristine graphene grown at 700 °C exhibited strong 2D peaks with an I(2D)/I(G) ratio > 2, while hydrogenated graphene synthesized at 500 °C showed increased defect density with an I(D)/I(G) ratio of ~1.

View Article and Find Full Text PDF

Study on Carbon Dioxide Capture Using Ternary Betaine-Based Deep Eutectic Solvents.

ACS Omega

December 2024

Key Laboratory of Metallurgical Engineering and Process of Energy Saving of Guizhou Province, College of Materials and Metallurgy, Guizhou University, Guiyang 550025, P.R. China.

The application of existing ternary betaine (Be)-based deep eutectic solvents (DESs) faces inevitable limitations due to the low regenerability and water absorption capability of the DESs. In this study, three ternary Be-based DESs with different molar ratios were prepared by adding the promoter diethanolamine (DEA) to the binary system of Be and ethylene glycol (EG). The effects of DEA, temperature, and flow rate on CO absorption by the Be-based DESs were then investigated.

View Article and Find Full Text PDF

Introduction: Preclinical studies have shown that oxygen therapy can improve ischaemic brain tissue oxygen tension, reduce reperfusion injury after revascularisation, promote neuroregeneration and inhibit inflammatory responses potentially exerting a beneficial effect after endovascular treatment (EVT) in patients with acute ischaemic stroke (AIS). However, the optimal fraction of inspired oxygen (FiO) during EVT under general anaesthesia is currently unknown. Therefore, we are conducting a randomised controlled trial (RCT) to evaluate the impact of high-concentration oxygen vs low-concentration normobaric oxygen on early neurological function after EVT.

View Article and Find Full Text PDF

In the realm of modern materials science, horizontally aligned carbon nanotube arrays stand as promising materials for the development of next-generation integrated circuits. However, their large-scale integration has been impeded by the constraints of current fabrication techniques, which struggle to achieve the necessary uniformity, density, and size control of carbon nanotube arrays. Overcoming this challenge necessitates a significant shift in fabrication approaches.

View Article and Find Full Text PDF

Quantifying the extent of desorption hysteresis is essential for establishing gas flow models. However, existing indices fail to adequately represent the changes in the actively mobile gas volume involved in transport, and experiments on the degree of hysteresis in negative-pressure environments are scarce. Therefore, this study conducted isothermal adsorption and desorption tests under both atmospheric- and negative-pressure conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!