A novel area controllable biosensing interface is designed on glassy carbon bead (GCB) and used for measurement of tetracycline (TET) in closed bipolar electrode-electrochemiluminescence (ECL) device. One face of GCB is modified with Au particles and the covered area is varied from 0 to 45.3% by tuning the external voltage during bipolar electrodeposition process in a home-made open bipolar electrochemical cell. It enables the conjugation of various amounts of biomolecules on Au/GCB. Then DNA walker and methylene blue (MB) labeled DNA (MB-DNA) are conjugated on Au surface for the following combination of aptamer. In the presence of target, aptamer partially hybridized with DNA walker will be released from Au surface, leading to the formation of dsDNA between DNA walker and MB-DNA. As a result, MB-DNA with recognition site for nicking endonuclease (Nb.BbvCI) in dsDNA is cleft into two segments by Nb.BbvCI. Meanwhile, the liberated DNA walker is triggered to continue the degradation of many MB-DNA. Due to the excellent electrochemical performance of MB, it is reduced at the cathode of BPE to amplify the ECL signal at the anode of BPE in a closed BPE-ECL platform. When the covered area of GCB by Au particles is enlarged from 10.1 to 45.3%, the change of ECL intensity could be increased 2.7-fold. The linear range for the detection of tetracycline is from 1 × 10 to 1 × 10 M with the detection limit of 6.0 × 10 M. Hence, controllable sensing area on a single glassy carbon bead, the amplification effect of DNA walker and MB make this approach possess many advantages over traditional biosensor.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2019.120404DOI Listing

Publication Analysis

Top Keywords

dna walker
20
area controllable
8
controllable sensing
8
bipolar electrode-electrochemiluminescence
8
detection tetracycline
8
glassy carbon
8
carbon bead
8
covered area
8
dna
6
walker
5

Similar Publications

To enhance the biomarker diagnostics sensitivity and selectivity of human papillomavirus type 16 oncoprotein E7 (HPV16 E7) in serum, a label/enzyme-free electrochemical detection platform was developed. This platform featured a type of "Super-turn-off" nanobiosensor monitored through differential pulse voltammetry (DPV). It integrated the magnetic self-assembly property of the α-FeO/FeO@Au/Sub/BSA signal transport nano-medium with the high specificity of CRISPR/Cas14a and the amplification capability of the bipedal walker (DNA walker composed of two ssDNA strands), resulting in the enhanced specificity and anti-interference performance while remaining stable at 4 °C for over 30 days.

View Article and Find Full Text PDF

Sensitive and accurate determination of acetamiprid is highly desirable for guaranteeing food safety. In this Letter, an energy-transfer-based dual-mode biosensor was developed using zinc-based metal-organic frameworks (Zn-MOFs) acting as both photoelectrochemical (PEC) and electrochemiluminescent (ECL) donors and Pt@CuO cubic nanocrystals (CNs) as the energy acceptor for detecting acetamiprid. By integration of aptamer recognition with two-step DNA circuit amplification (entropy-driven DNA cycle and DNA walker), the detection of acetamiprid was converted into the assay of abundant intermediate DNA strands.

View Article and Find Full Text PDF

In this study, we developed a novel strategy for effective bacteria capture, elimination, and detection. The aptamer of Staphylococcus aureus (S. aureus) was immobilized on FeO NPs and partly hybridized with the T strand, which exhibited good bacterial capture efficiency.

View Article and Find Full Text PDF

Aptamer-based DNAzyme walker electrochemical biosensing strategy for Acinetobacter baumannii detection.

Bioelectrochemistry

December 2024

Department of Laboratory Medicine, The Affiliated Hospital of Southwest Medical University, 25 Taiping Street, Luzhou 646000, Sichuan, China; Sichuan Province Engineering Technology Research Center of Molecular Diagnosis of Clinical Diseases, China; Molecular Diagnosis of Clinical Diseases Key Laboratory of Luzhou, Sichuan, China. Electronic address:

In this study, an innovative electrochemical biosensor was developed for the rapid, specific, and sensitive detection of Acinetobacter baumannii without the need for sample pretreatment. The biosensor utilized an aptamer as a specific capture probe for A. baumannii and employed a self-powered DNAzyme walker cleavage cycle reaction to achieve signal amplification.

View Article and Find Full Text PDF

The anomalous expression of microRNA poses a serious threat to human life and health safety, and serves as an important biomarker for cancer detection. In this study, a novel magnetic-assisted DNA logic gate nanomachine triggered by miRNA-21 and miRNA-155 was designed based on the trans-cleavage activity of CRISPR/Cas12a activated by a split DNA activator, using only a single crRNA and signal probe, which simplified the detection procedure and complex nucleic acid amplification. The presence of target molecules, miRNA-21 and miRNA-155, can stimulate the DNA walker machine assembled on magnetic beads, which releases activator under the action of DNAzyme.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!