Objective The Chicago classification using high-resolution manometry (HRM) has been proposed for the diagnosis of esophageal motility disorders. However, HRM is expensive, and few patients are likely to benefit from this method. We established a method using a raised infusion catheter called "esophageal manometry using a trans-nasal endoscope". In this study, we examined the clinical utility of this new method for the assessment of patients with dysphagia. Methods We enrolled 124 consecutive patients who complained of dysphagia and were suspected of having esophageal motility disorders. Patients underwent manometry using a trans-nasal endoscope at Hiroshima University Hospital from September 2008 to December 2018. An esophageal biopsy was performed during the procedure from the thoracic esophagus to detect eosinophilic esophagitis. In addition, we examined the clinical courses of patients diagnosed with achalasia. Results The diagnostic ability of manometry using a trans-nasal endoscope was 98%, and no major complications associated with the procedure were recorded. About 30% of patients were diagnosed with achalasia, and most (77%) were well controlled by medications or balloon dilation. One patient was diagnosed with eosinophilic esophagitis. Conclusion Manometry using a trans-nasal endoscope is beneficial and can be used for the clinical management of patients with dysphagia.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7184087PMC
http://dx.doi.org/10.2169/internalmedicine.3734-19DOI Listing

Publication Analysis

Top Keywords

manometry trans-nasal
20
trans-nasal endoscope
16
esophageal motility
12
motility disorders
8
examined clinical
8
patients dysphagia
8
eosinophilic esophagitis
8
patients diagnosed
8
diagnosed achalasia
8
patients
7

Similar Publications

Training for Awake, Office-Based Laryngeal Procedures-The Laryngology Fellow's Perspective.

Laryngoscope

February 2024

Brigham & Women's Hospital, Department of Surgery, Division of Otolaryngology, Harvard University, Boston, Massachusetts, U.S.A.

Objective: The aim was to explore recent laryngology graduates' perspectives on their experience, competency, and challenges learning office-based procedures during fellowship training in the United States and Canada.

Methods: Anonymous 22-item questionnaire survey was distributed electronically to fellowship-trained laryngologists having completed fellowship within past 5 years.

Results: Ninety fellowship-trained laryngologists between 2018 and 2022 were surveyed.

View Article and Find Full Text PDF

Purpose: Computational fluid dynamics (CFD)-based calculation of intranasal airflow became an important method in rhinologic research. Current evidence shows weak to moderate correlation as well as a systematic underprediction of nasal resistance by numerical simulations. In this study, we investigate whether these differences can be explained by measurement uncertainties caused by rhinomanometric devices and procedures.

View Article and Find Full Text PDF

Objective The Chicago classification using high-resolution manometry (HRM) has been proposed for the diagnosis of esophageal motility disorders. However, HRM is expensive, and few patients are likely to benefit from this method. We established a method using a raised infusion catheter called "esophageal manometry using a trans-nasal endoscope".

View Article and Find Full Text PDF

A prospective study evidencing rhinomanometric and olfactometric outcomes in women taking oral contraceptives.

Hum Reprod

November 2001

Department of Microbiological Science and Gynaecological Science, Research Group for Sexology, University of Catania, Catania, Italy.

Background: The aim of this prospective study was to evaluate the changes in olfactory sensitivity of oral contraceptive (pill) users.

Methods: Sixty women underwent rhinomanometric and olfactometric determinations during the follicular, periovular and luteal phases of the menstrual cycle, and at day 7, 14 and 21 of contraceptive intake. Thirty-one women used 30 microg ethinyl oestradiol plus 75 microg gestodene and 29 women used 20 microg ethinyl oestradiol plus 150 microg desogestrel.

View Article and Find Full Text PDF

Characterization of nasal airflow.

Clin Otolaryngol Allied Sci

October 1997

Department of Medical Computing and Statistics, University of Wales College of Medicine, Cardiff, UK.

Nasal airflow and trans-nasal pressure difference was measured by active anterior rhinomanometry in 24 subjects. An analysis was undertaken to determine the 'goodness of fit' of two models used to characterize nasal airflow, one model by Broms and the other by O'Neill and Tolley. A judicious approach to choice of fit criterion led to the conclusion that the latter model provided a more accurate characterization of nasal airflow.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!