The objective was to compare outcomes of the volar, Chamay and tendon splitting approaches for proximal interphalangeal joint arthroplasty using a surface-replacing implant (CapFlex-PIP). One-hundred prospectively documented patients with a 2-year follow-up were included. Range of proximal interphalangeal joint motion, the brief Michigan Hand Outcomes Questionnaire and complications were analysed. Between baseline and follow-up, mean proximal interphalangeal joint motion increased for the volar (53° to 54°), Chamay (38° to 53°) and tendon splitting (40° to 61°) approaches. The volar approach yielded the greatest flexion and the highest extension deficit. The mean brief Michigan Hand Outcomes Questionnaire scores at baseline and 2 years were 45 and 74 (volar), 45 and 66 (Chamay) and 41 and 75 (tendon splitting). Seven patients in the Chamay group and two in the volar group required a reoperation consisting of teno-/arthrolysis. The tendon splitting approach tended to result in the best outcomes that were associated with fewer complications compared with the volar and Chamay approaches. IV.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1753193419891382DOI Listing

Publication Analysis

Top Keywords

proximal interphalangeal
16
interphalangeal joint
16
tendon splitting
16
volar chamay
12
approaches proximal
8
joint arthroplasty
8
arthroplasty surface-replacing
8
surface-replacing implant
8
chamay tendon
8
joint motion
8