Effect of Shaft Length on the Torsional Resistance of Rotary Nickel-titanium Instruments.

J Endod

Department of Conservative Dentistry, School of Dentistry, Dental Research Institute, Pusan National University, Yangsan, Korea. Electronic address:

Published: February 2020

Introduction: This study was conducted to evaluate the effect of file length on the torsional resistance of nickel-titanium rotary files.

Methods: Forty-five new files with a #25 tip size and variable taper for ProTaper Next (PTN; Dentsply Sirona, York PA), ProTaper Gold (PTG, Dentsply Sirona), and HyFlex CM (HCM; Coltene-Whaledent, Allstetten, Switzerland) were divided into 3 subgroups (n = 15) according to the file length (21, 25, and 31 mm). Torsional tests were performed using a custom-made device (AEndoS; DMJ System, Busan, Korea). The maximum torsional load and distortion angle were measured until file fracture occurred. The toughness was calculated using these data. All data were statistically analyzed using 2-way analysis of variance at a confidence level of 95%. One-way analysis of variance and Duncan post hoc comparison were also conducted to assess the difference among the independent variables, shaft length, and file system.

Results: A statistically significant interaction was observed between the file system and instrument length with respect to the maximum torsional load (P < .05). The 31-mm shaft length of HCM showed higher maximum torsional load than that of the 25- and 21-mm shaft length in the HCM groups (P < .05). Among the instrument systems, PTG showed the significantly highest maximum torsional load followed by PTN and HCM (P < .05). The 31-mm shaft length of PTG showed significantly higher toughness than that of the 21- and 25-mm shaft lengths (P < .05), whereas PTN and HCM did not show any difference in relation to the shaft length.

Conclusions: Within the limitations of this study, the instrument with a longer shaft may have higher maximum torsional load or toughness than that with a shorter shaft.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.joen.2019.10.019DOI Listing

Publication Analysis

Top Keywords

shaft length
20
maximum torsional
20
torsional load
20
length torsional
12
shaft
9
torsional
8
torsional resistance
8
file length
8
dentsply sirona
8
analysis variance
8

Similar Publications

Background: This study examines the relationship between the anterior offset of the tibial intramedullary nail (TIN) entry point and the tibial shaft axis to enhance the fit and alignment of TINs, using transparent 3D-CT in an accurate lateral view to minimize rotational artifacts.

Methods: Data were collected from 100 adult patients undergoing tibial CT scans. Measurements included the anterior offset from the tibial axis to the entry point, tibial tubercle offset, tibial plateau length, posterior slope, tibial length, isthmus diameter, and the isthmus-to-tibial length ratio.

View Article and Find Full Text PDF

Background: The medial malleolus is involved in up to 50 % of ankle fractures. When surgery is required, a thorough understanding of bone mass distribution within the distal tibia is crucial for selecting and positioning screws to ensure stable fixation. Despite its clinical significance, data on the bone mass distribution in the distal tibia remains limited.

View Article and Find Full Text PDF

Background: Length unstable femoral shaft fractures in school-aged children usually demand surgical treatment, but the optimal choice remains controversial, especially in overweight adolescents. This study aimed to compare the clinical results of locking compression plates (LCP) and elastic stable intramedullary nails (ESIN) combined with temporary external fixator (TEF) in school-aged children weighing over 50 kg.

Methods: Between January 2010 and January 2018, children over 50 kg with length unstable femoral shaft fracture treated with ESIN & EF in the authors' institute were included in this study.

View Article and Find Full Text PDF

This study investigates the nonlinear dynamics of a system with frequency-dependent stiffness using a MEMS-based capacitive inertial sensor as a case study. The sensor is positioned directly on a rotating component of a machine and consists of a microbeam clamped at both ends by fixed supports with a fixed central proof mass. The nonlinear behavior is determined by electrostatic forces, axial and bending motion coupling, and frequency-dependent stiffness.

View Article and Find Full Text PDF

Objectives: To compare the consolidation quality between the anteromedial aspect of regenerated bone (AMRB) and other areas of regenerated bone (TORB) following the induced membrane technique (IMT) for managing critical-sized tibial shaft bone defects, and determine the factors affecting consolidation quality in the AMRB.

Methods: Design: Retrospective comparative study.

Setting: Academic Level I trauma center.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!