A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Low-profile locking-plate vs. the conventional AO system: early comparative results in wrist arthrodesis. | LitMetric

Low-profile locking-plate vs. the conventional AO system: early comparative results in wrist arthrodesis.

Arch Orthop Trauma Surg

Department of Hand, Plastic and Reconstructive Surgery, Burn Center, BG Trauma Center Ludwigshafen, Ludwig-Guttmann Str. 13, 67071, Ludwigshafen, Germany.

Published: March 2020

Introduction: Total wrist arthrodesis represents a reliable salvage procedure for severe painful conditions of the wrist. To date, wrist arthrodesis using a dorsal plate reaching from the distal radius to the third metacarpal is still recommended. A new implant (APTUS© 2.5 TriLock Wrist Fusion Plate, Medartis Suisse) that does not cross the third carpometacarpal joint (CMCJ-3) has been introduced recently. The purpose of this retrospective study was to compare both implants concerning early functional and clinical results.

Materials And Methods: A total of 20 patients underwent total wrist arthrodesis [10, using the new APTUS© implant (APT); 10 using the Depuy-Synthes© LCP plates (AO)]. The postoperative control interval was 18.2 and 37.2 months in APT and AO, respectively. Clinical assessment included functional parameters such as active range of motion (AROM) for pronation and supination, grip strength, and passive range of motion of the CMCJ-3. Additionally the DASH score and the Krimmer wrist score as well as pain levels at rest and under stress conditions were evaluated.

Results: All patients showed osseous healing without complications except one case of non-union in APT. There were no significant differences between both groups concerning grip strength, AROM of the wrist, pain levels, DASH- and Krimmer Score. APT showed a significantly increased passive range of motion of the CMCJ-3 compared to the unaffected contralateral side.

Conclusions: The new implant shows similar functional results compared to the standard procedure. The main advantage of the new implant is the fact that no implant removal is necessary due to the unaffected CMCJ-3. Furthermore the mobility of the CMCJ slightly increased and showed positive impact on hand kinematics.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00402-019-03314-4DOI Listing

Publication Analysis

Top Keywords

wrist arthrodesis
16
range motion
12
wrist
8
total wrist
8
grip strength
8
passive range
8
motion cmcj-3
8
pain levels
8
implant
5
low-profile locking-plate
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!