A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Technical Note: Performance comparison of ultra-high-resolution scan modes of two clinical computed tomography systems. | LitMetric

Purpose: Two ultra-high-resolution (UHR) computed tomography (CT) scanners are clinically available. One is achieved by a CT system with a 0.25 mm × 160 row detector (Detector-UHR), whereas the other is with a 0.6 mm × 32 row detector with in-plane comb filtering in a dual source CT (Comb-UHR). We compared radiation dose efficiencies of the two UHR modes to that of a routine scan mode (RS), using physical image quality measures for an assumed condition of abdominal CT angiography (CTA).

Methods: A wire phantom, a 300-mm cylindrical water bath phantom, and a microdisk phantom were used for measuring the modulation transfer function (MTF), noise power spectrum (NPS), and slice sensitivity profiles (SSP), respectively, at CTDI of 20 mGy. Images with minimal slice thicknesses were reconstructed by filtered back projection methods. System performance functions (SPF ) based on the prewhitening theorem were calculated by dividing MTF by NPS measurements. The ideal observer's detectability index (d' ) was also estimated for a task corresponding to a 1-mm diameter vessel. Furthermore, a bar-pattern phantom placed in a water phantom resembling an adult abdomen was scanned, and the visibility of the bars was observed.

Results: System performance function (SPF ) results showed that Comb-UHR has a 70% dose efficiency compared to RS and provides better than twofold SPF compared to Detector-UHR. The d' values of Detector-UHR, Comb-UHR, and RS were 6.5, 14.7, and 16.0, respectively. Although the bar-pattern phantom images were consistent with the SPF results, bar widths < 1.0 mm for Detector-UHR and < 0.75 mm for Comb-UHR and RS were not resolved.

Conclusions: Though both the UHR modes exhibited system performances extending to 2.6 cycles/mm, they appeared not to be advantageous compared to RS in the conditions applicable to abdominal CTA, because of their insufficient dose efficiencies.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.13949DOI Listing

Publication Analysis

Top Keywords

computed tomography
8
row detector
8
system performance
8
bar-pattern phantom
8
phantom
6
technical note
4
note performance
4
performance comparison
4
comparison ultra-high-resolution
4
ultra-high-resolution scan
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!