Soft denture liners and tissue conditioners are widely used for the denture patients to cushion masticatory force and condition abused tissues, respectively. This study assessed methods for the evaluation of the viscoelasticity and glass transition temperature (T) of the silicone permanent soft liner, acrylic permanent soft liner, and tissue conditioner. Three rheological parameters of storage modulus (E'), loss modulus (E''), and loss tangent ([Formula: see text]), T, and hardness were determined using dynamic mechanical analysis (DMA), differential scanning calorimetry (DSC), and the Shore A0 hardness test. Five specimens were measured for each material. The time-temperature superposition principle was applied to produce master curves of E', E'', and [Formula: see text] for the tested materials at a reference temperature of 37 °C. The acrylic permanent soft liner and tissue conditioner exhibited viscoelastic behavior and sensitivity to frequency, especially at lower frequencies. The silicone permanent soft liner showed elastic behavior and was frequency-independent. T for the acrylic permanent soft liner was higher than that for the tissue conditioner, which in turn was higher than that for the silicone permanent soft liner for both DMA and DSC. In DMA, a higher frequency led to higher T values. A positive linear relationship was found between Shore A0 hardness and E' values, but not E'' and [Formula: see text] values. Shore hardness reflects elasticity, but not viscosity. The results of the present study can be used to improve methods for evaluating the viscoelasticity and T of soft denture liners and tissue conditioners.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10266-019-00477-9DOI Listing

Publication Analysis

Top Keywords

soft liner
24
permanent soft
20
tissue conditioner
16
soft denture
12
denture liners
12
liners tissue
12
acrylic permanent
12
[formula text]
12
shore hardness
12
soft
9

Similar Publications

Total hip arthroplasty (THA) is a highly effective surgical intervention for end-stage hip joint disorders. While common complications such as infection, dislocation, and prosthetic loosening are well-documented, rarer complications remain underreported. One such complication is foreign body interposition on the bearing surface, which can compromise joint mechanics and adversely affect outcomes.

View Article and Find Full Text PDF

Introduction The cushion effect of soft liners serves to distribute the mastication forces and stresses more evenly, along with absorbing energy. Instead, soft liners can act as a nidus for microbial growth, especially Candida species. An accumulation of these fungi is a problem encountered during the clinical use of them, especially in immunocompromised individuals.

View Article and Find Full Text PDF

Prosthetic bone and joint infections are difficult to treat with varying levels of success with standard therapy. Synthetic calcium sulfate carrier, to which specific antibiotics can be added, can be utilized as an alternative drug delivery system in these cases. We have reviewed clinical outcomes using commercially available pure synthetic calcium sulfate dissolvable beads (Stimulan) loaded with antibiotics in 143 patients undergoing orthopedic surgery for prevention and treatment of joint infection.

View Article and Find Full Text PDF

Tensile bond strength of soft relining materials to CAD-CAM denture base materials.

J Prosthodont

December 2024

Division of Comprehensive Oral Health, Department of Restorative Sciences, School of Dentistry, Birmingham, Alabama, USA.

Purpose: This study aimed to investigate the tensile bond strength between soft relining materials and different denture base materials.

Materials And Methods: The study was conducted in accordance with ISO 23401:2023. A total of 288 rectangular specimens (10L × 10H × 20W mm) were fabricated from various denture base materials, including a heat-compression polymethylmethacrylate (PMMA), two types of milled PMAA, and three types of 3D-printed resins, with bonding using two chairside soft reline materials (Coe-Soft and Lynal).

View Article and Find Full Text PDF
Article Synopsis
  • * This study compares the effectiveness of conventional maxillofacial obturators versus those lined with a soft-liner, examining their impact on masticatory performance, speech, and quality of life in patients.
  • * Results show that the relined obturator significantly improves masticatory performance (3.22 vs. 2.74) and speech quality (lower jitter), highlighting the benefits of using a soft-liner in prosthetic rehabilitation.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!