A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Meta-analysis on efficacy of auto fluorescence in detecting the early dysplastic changes of oral cavity. | LitMetric

Background: Light-based detection agents using autofluorescence may be helpful in the detection of early dysplasia, which would otherwise be misdiagnosed as nondysplastic by conventional oral examination (COE) with white light. Visually-enhanced lesion scope (VELscope) is one of such an aid used for the purpose. A meta-analysis was carried out on the sensitivity and specificity of VELscope that would enable in providing evidence of its usage in oral dysplasia.

Materials And Methods: MeSH terms such as auto florescence in oral dysplasia, VELscope, Oral ID, Identifi, in a different medical database such as PubMed, Cochrane, EBSCO, and Google scholar was carried out by four research associates. The total articles available were 242, of which, 230 were excluded based on strict criteria of randomized control trials and proper design. Finally, only 12 studies were chosen for the present analysis. Of 1643 patients from 12 studies, 1264 patients had undergone the autofluorescence examination after the COE. Only 774 patients have shown the loss of fluorescence with VELScope examination and 487 had retained the fluorescence. Biopsy was performed on 1176 patients after the autofluorescence examination in the areas where there was the loss of fluorescence. The available data were subjected to software Review Manager for analysis.

Results And Discussion: Of the 11 studies analyzed, majority of them showed that the autofluorescence device were sensitive enough > 0.70; however, the values of sensitivity and specificities varied significantly. With the VELscope the diagnostic performance of the inexpert examiner was not improved, obtaining a sensitivity of 0.40 (95% of confidence interval [CI]: 0.406-0.773) and a specificity of 0.80 (95% CI: 0.614-0.923).

Conclusion: The new technique may help as an adjunct to histopathology in detecting the dysplasia initially and stop further progression to the carcinoma.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6852629PMC
http://dx.doi.org/10.4103/sajc.sajc_336_18DOI Listing

Publication Analysis

Top Keywords

examination coe
8
autofluorescence examination
8
loss fluorescence
8
oral
5
velscope
5
meta-analysis efficacy
4
efficacy auto
4
fluorescence
4
auto fluorescence
4
fluorescence detecting
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!