Objective measurement is important for diagnosing congenital or acquired auricular abnormalities and the evaluation of therapeutic efficacy. However, methods applied in the past were mostly inaccurate and unreliable. The present study aimed to introduce five standardized indices for auricle measurement and present a highly precise and reliable methodology combining three-dimensional (3D) scanning techniques and the Materialise Mimics software for the evaluation of auricle sizes. A total of 20 normal ears were measured independently by four surgeons using the standardized digital method with 3D scanning technique and the traditional manual method. Parameters of the auricle, including the length and width, arc length, cranioauricular height and angle were measured using the Mimics software. Paired t-test, Wilcoxon signed rank test and intra-class correlation coefficients (ICC) were performed on the data to assess the precision, uniformity and observer independence of the method. Pearson's product moment correlation was calculated to assess the correlation between auricle length and width in addition to the correlation between cranioauricular height and angle. No significant differences were indicated between measurements of five auricular parameters made by two surgeons using the digital method. However, significant differences were found using the manual method (P<0.01). ICC values derived from digital measurements ranged from 0.901 to 0.987, whereas those derived from manual measurements ranged from 0.526 to 0.807. These results suggested that the standardized digital method was replicable and reliable compared with the traditional manual method. Pearson's coefficient analysis showed that there was a significant correlation between cranioauricular height and angle (P<0.05), but no correlations were found between the height and width of the auricle (P>0.05). Taken together, data from the present study suggested that measurements of the length and width, arch length, and cranioauricular height and angle of auricles using the standardized digital method combining 3D scanning with the Mimics software were comprehensive, precise, convenient, repeatable and reliable.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6878875PMC
http://dx.doi.org/10.3892/etm.2019.8159DOI Listing

Publication Analysis

Top Keywords

mimics software
12
digital method
8
manual method
8
length width
8
cranioauricular height
8
height angle
8
method
6
auricle
5
standardized measurement
4
measurement auricle
4

Similar Publications

The best treatment method for reverse obliquity intertrochanteric fractures (ROIFs) is still under debate. Our team designed the modified proximal femoral nail (MPFN) specially for treating such fractures. The objective of this research was to introduce the MPFN device and compare the biomechanical properties with Proximal Femoral Nail Antirotation (PFNA) and InterTAN nail via finite element modelling.

View Article and Find Full Text PDF

The repercussions of hormone replacement therapy (HRT) and bisphosphonates pose serious clinical challenges and warrant novel therapies for osteoporosis in menopausal women. To confront this issue, the present research aimed to design and fabricate daidzein (DZ); a phytoestrogen-loaded hydroxyapatite nanoparticles to mimic and compensate for synthetic estrogens and biomineralization. Hypothesizing this bimodal approach, hydroxyapatite nanoparticles (HAPNPs) were synthesized using the chemical-precipitation method followed by drug loading (DZHAPNPs) via sorption.

View Article and Find Full Text PDF

Objectives: This study aims to evaluate the changes in the mandibular canal following the treatment of large odontogenic keratocysts through decompression and curettage, providing a theoretical basis for sequential treatment.

Methods: Twenty patients were selected for each decompression and curettage treatment of large odontogenic keratocysts in the mandible. Postoperative follow-up with was conducted every three months, during which cone beam computed tomography (CBCT) scans were performed.

View Article and Find Full Text PDF

Objective: This study aims to analyze anatomical parameters of the transmission route of sigmoid sinus tinnitus (SST) to explore its mechanism and speculate on possible responsible anatomical abnormalities.

Methods: Clinical data were retrospectively collected from SST and sigmoid sinus wall dehiscence (SSWD) patients suggested by temporal bone high resolution computed tomography (HRCT), with and without tinnitus, at the First Affiliated Hospital of Chongqing Medical University from January 2015 to August 2022. Patients were divided into SSWD tinnitus ( = 61), and non-tinnitus ( = 60) groups based on HRCT features.

View Article and Find Full Text PDF

Objective: This study aims to evaluate the association between the white blood cell-to-platelet ratio (WPR) and 28-day all-cause mortality among patients experiencing cardiac arrest.

Methods: Utilizing data from 748 cardiac arrest patients in the Medical Information Mart for Intensive Care-IV (MIMIC-IV) 2.2 database, machine learning algorithms, including the Boruta feature selection method, random forest modeling, and SHAP value analysis, were applied to identify significant prognostic biomarkers.

View Article and Find Full Text PDF