AI Article Synopsis

Article Abstract

Purpose: Beta-ray imaging systems are widely used for various biological objects to obtain a two-dimensional (2D) distribution of β-ray emitting radioisotopes. However, a conventional β-ray imaging system is unsuitable for multiple-tracer imaging, because the continuous energy distribution of β-rays complicates distinguishing among different tracers by energy information. Therefore, we developed a new type of β-ray imaging system, which is useful for multiple tracers by detecting coincidence γ-rays with β-rays, and evaluated its imaging performance.

Methods: Our system is composed of position-sensitive β-ray and γ-ray detectors. The former is a 35 × 35 × 1-mm Ce-Doped((La, Gd) Si O ) (La-GPS) scintillation detector, which has a 300-µm pitch of pixels. The latter is a 43 × 43 × 16-mm bismuth germanium oxide (BGO) scintillation detector. Both detectors are mounted on a flexible frame and placed in a user-selectable position. We experimentally evaluated the performance of the β-ray detector and the γ-ray efficiencies of the γ-ray detector with different energies, positions, and distances. We also conducted point sources and phantom measurements with dual isotopes to evaluate the system performance of multiple-tracer imaging.

Results: For the β-ray detector, the β-ray detection efficiencies for Ca (245-keV maximum energy) and Sr/ Y (545 and 2280-keV maximum energy) were 14.3% and 21.9%, respectively. The total γ-ray detection efficiency of the γ-ray detector for all γ-rays from Na (511-keV annihilation γ-rays and a 1275-keV γ-ray) in the center position with a detector distance of 20 mm was 17.5%. From a point-source measurement using Na and Sr/ Y, we successfully extracted the position of a positron-γ emitter Na. Furthermore, for a phantom experiment using Ca and F or F and Na, we successfully extracted the distribution of the second tracer using the annihilation γ-ray or de-excitation γ-ray coincidence. In all the imaging experiments, the event counts of the extracted images were consistent with the counts estimated by the measured γ-ray efficiencies.

Conclusions: We successfully demonstrated the feasibility of our β-ray autoradiography system for imaging multiple isotopes. Since our system can identify not only a β-γ emitter but also a positron emitter using the coincidence detection of annihilation γ-rays, it is useful for PET tracers and various new applications that are otherwise impractical.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.13947DOI Listing

Publication Analysis

Top Keywords

imaging system
12
γ-ray
10
beta-ray imaging
8
γ-ray coincidence
8
imaging
8
multiple-tracer imaging
8
β-ray
8
β-ray imaging
8
scintillation detector
8
β-ray detector
8

Similar Publications

A conformational switch-controlled RNA sensor based on orthogonal dCas12a for RNA imaging in live cells.

Biosens Bioelectron

January 2025

Lab of Biosystem and Microanalysis, State Key Laboratory of Bioreactor Engineering, Shanghai Collaborative Innovation Center for Biomanufacturing Technology, East China University of Science and Technology, Shanghai, 200237, China; School of Chemistry and Chemical Engineering, Shihezi University, Xinjiang, 832000, China. Electronic address:

RNA imaging technology is essential for understanding the complex RNA regulatory mechanisms and serves as a powerful tool for disease diagnosis. However, conventional RNA imaging methods often require multiple fluorescent tags for the specific labeling of individual targets, complicating both the imaging process and subsequent analysis. Herein, we develop an RNA sensor that integrates a blocked CRISPR RNA (crRNA)-based conformational switch with a controllable CRISPR activation (CRISPRa) system and apply for RNA imaging.

View Article and Find Full Text PDF

Loneliness is associated with different structural brain changes in schizophrenia spectrum disorders and major depression.

Schizophr Res

January 2025

Department of Psychiatry and Psychotherapy, Central Institute of Mental Health, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany; German Center for Mental Health (DZPG), partner site Mannheim-Heidelberg-Ulm, Germany. Electronic address:

Background: Loneliness, distress from having fewer social contacts than desired, has been recognized as a significant public health crisis. Although a substantial body of research has established connections between loneliness and various forms of psychopathology, our understanding of the neural underpinnings of loneliness in schizophrenia spectrum disorders (SSD) and major depressive disorder (MDD) remains limited.

Methods: In this study, structural magnetic resonance imaging (sMRI) data were collected from 57 SSD and 45 MDD patients as well as 41 healthy controls (HC).

View Article and Find Full Text PDF

Background: To reduce the mortality related to bladder cancer, efforts need to be concentrated on early detection of the disease for more effective therapeutic intervention. Strong risk factors (eg, smoking status, age, professional exposure) have been identified, and some diagnostic tools (eg, by way of cystoscopy) have been proposed. However, to date, no fully satisfactory (noninvasive, inexpensive, high-performance) solution for widespread deployment has been proposed.

View Article and Find Full Text PDF

Atrial cardiomyopathy (AC) has been defined by the European Heart Rhythm Association as "Any complex of structural, architectural, contractile, or electrophysiologic changes in the atria with the potential to produce clinically relevant manifestations".1 The left atrium (LA) plays a key role in maintaining normal cardiac function; in fact atrial dysfunction has emerged as an essential determinant of outcomes in different clinical scenarios, such as valvular diseases, heart failure (HF), coronary artery disease (CAD) and atrial fibrillation (AF). A comprehensive evaluation, both anatomical and functional, is routinely performed in cardiac imaging laboratories.

View Article and Find Full Text PDF

N-heterocyclic carbene (NHC)-protected gold nanoclusters display high stability and high photoluminescence, making them well-suited for fluorescence imaging and photodynamic therapeutic applications. We report herein the synthesis of two bisNHC-protected Au nanoclusters with π-extended aromatic systems. Depending on the position of the π-extended aromatic system, changes to the structure of the ligand shell in the cluster are observed, with the ability to correlate increases in rigidity with increases in fluorescence quantum yield.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!