Background: Published studies indicate that assessments of goblet cell density using conjunctival impression cytology has provided very variable results, but the reasons for this are unclear. Systematic analyses of the sources of variability are required.

Methods: From 20 healthy young adults, conjunctival impression cytology specimens were obtained using a supported filter unit applied to the superior bulbar conjunctiva. The filters were stained with Giemsa and 10 non-overlapping, randomly selected high-power field images were obtained from each specimen and the numbers of goblet cells per high-power field counted.

Results: From all 200 high-power fields assessed, the numbers of goblet cells ranged from zero to 74, with an overall mean value of 11.6 ± 14.8 per high-power field. From each successive set of 10 microscope field images from all individuals, the average number of goblet cells ranged from 23.2 in the first high-power field that obviously included numerous goblet cells down to 6.2 per high-power field. As the outcome from multiple counts/individual was systematically increased, these averages progressively decreased from 23.2 to 11.6 per high-power field, and while the standard deviation values also progressively declined (from 7.9 to 5.5 per high-power field), the relative variability (as the co-efficient of variation) did not, and increased to averaged values of over 100 per cent.

Conclusions: These analyses indicate that there is a benefit of making multiple counts of goblet cells from different high-power fields, but that there is no obvious benefit of using more than five to seven high-power fields for any particular specimen.

Download full-text PDF

Source
http://dx.doi.org/10.1111/cxo.13007DOI Listing

Publication Analysis

Top Keywords

high-power field
28
goblet cells
24
high-power fields
16
conjunctival impression
12
impression cytology
12
cells high-power
12
high-power
11
field
8
field images
8
numbers goblet
8

Similar Publications

A ridge-loaded staggered double-vane slow-wave structure is proposed for terahertz radiation sources employing a sheet electron beam. This slow-wave structure has the advantages of enhanced electric field and energy density distribution and improved interaction impedance in the beam-wave interaction region. High-frequency characteristics are investigated for the proposed slow wave structure and compared with those of the staggered double-vane slow wave structure.

View Article and Find Full Text PDF

In this paper, a new label-free DNA nanosensor based on a top-gated (TG) metal-ferroelectric-metal (MFM) graphene nanoribbon field-effect transistor (TG-MFM GNRFET) is proposed through a simulation approach. The DNA sensing principle is founded on the dielectric modulation concept. The computational method employed to evaluate the proposed nanobiosensor relies on the coupled solutions of a rigorous quantum simulation with the Landau-Khalatnikov equation, considering ballistic transport conditions.

View Article and Find Full Text PDF

Relaxor ferroelectric film capacitors exhibit high power density with ultra-fast charge and discharge rates, making them highly advantageous for consumer electronics and advanced pulse power supplies. The Aurivillius-phase bismuth layered ferroelectric films can effectively achieve a high breakdown electric field due to their unique insulating layer ((BiO) layer)). However, designing and fabricating Aurivillius-phase bismuth layer relaxor ferroelectric films with optimal energy storage characteristics is challenging due to their inherently stable ferroelectric properties.

View Article and Find Full Text PDF

Although the Doppler velocity log is widely applied to measure underwater fluid flow, it requires high power and is inappropriate for measuring low flow velocity. This study proposes a fluid flow sensor that utilizes optical flow sensing. The proposed sensor mimics the neuromast of a fish by attaching a phosphor to two pillar structures (A and B) produced using ethylene propylene diene monomer rubber.

View Article and Find Full Text PDF

Silicone gel, used in the packaging of high-voltage, high-power semiconductor devices, generates bubbles during the packaging process, which accelerates the degradation of its insulation properties. This paper establishes a testing platform for electrical treeing in silicone gel under pulsed electric fields, investigating the effect of pulse voltage amplitude on bubble development and studying the initiation and growth of electrical treeing in a silicone gel with different pulse edge times. The relationship between bubbles and electrical treeing in silicone gel materials is discussed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!