While multifocal intraocular lenses (MIOLs) are increasingly implanted to correct for presbyopia, how one sees with a multifocal correction is hard to explain and imagine. The current study evaluates the quality of various visual simulating technologies by comparing vision with simulated MIOLs pre-operatively and the implanted MIOLs post-operatively in the same patients. Two simulation platforms were used: (1) a custom-developed adaptiveoptics (AO) system, with two visual simulator devices: a spatial light modulator (SLM) and an optotunable lens operating under temporal multiplexing (SimVis); and (2) a wearable, binocular, large field of view SimVis2Eyes clinical simulator (SimVis Gekko, 2Eyes Vision, Madrid, Spain). All devices were programmed to simulate a trifocal diffractive MIOL (POD F, FineVision, PhysIOL). Eight patients were measured pre-operatively simulating the trifocal lens and post-operatively with implantation of the same MIOL. Through-focus decimal visual acuity (TF VA) was measured (1) monocularly in monochromatic light using a four-alternative-forced-choice procedure in the AO system; and (2) binocularly using a clinical optotype in white light. Visual simulations pre-operatively predict well the TF VA performance found post-operatively in patients implanted with the real IOL. The average RMS difference between TF curves with the different visual simulators was 0.05 ± 0.01. The average RMS difference between the TF VA curves with the SimVis pre-operatively and the real MIOL post-operatively was 0.06 ± 0.01 in both platforms, and it was higher in cataract eyes (0.08 ± 0.01, on average across simulators) than in eyes with clear lens. In either group the shape of the TF curves is similar across simulators and pre- and post-operatively. TF curves cross-correlated significantly between simulators (lag k = 0, rho = 0.889), as well as with results with the real MIOL implanted (lag k = 0, rho = 0.853). Visual simulations are useful programmable tools to predict visual performance with MIOLs, both in an AO environment and in a clinical simulator. Pre-operative visual simulations and post-operative data are in good agreement.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6865107 | PMC |
http://dx.doi.org/10.1364/BOE.10.005801 | DOI Listing |
Int J Biol Macromol
January 2025
Department of Biotechnological Genetics, Institute of Science, Trakya University, Edirne, Turkey.
Fish gelatin, a sustainable substitute for mammalian gelatin, frequently exhibits weaker gel strength and thermal stability, limiting its industrial uses. This study investigated an in vivo method to improve functional characteristics by supplementing Nile tilapia diets with Aronia extract. The control diet (A0) contained no Aronia extract, while the remaining four diets consisted of commercial pelleted feed enriched with 250 mg/kg (A250), 500 mg/kg (A500), 750 mg/kg (A750), and 1000 mg/kg (A1000) of Aronia extract.
View Article and Find Full Text PDFExp Brain Res
January 2025
Institute for Experimental Psychology, Heinrich Heine University Düsseldorf, 40225, Düsseldorf, Germany.
When we touch ourselves, the pressure appears weaker compared to when someone else touches us, an effect known as sensory attenuation. Sensory attenuation is spatially tuned and does only occur if the positions of the touching and the touched body-party spatially coincide. Here, we ask about the contribution of visual or proprioceptive signals to determine self-touch.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Anaesthesiology and Intensive Care, Hospital Canselor Tuanku Muhriz, Universiti Kebangsaan Malaysia, Kuala Lumpur 56000, Malaysia.
Regional anaesthesia has seen a resurgence of sorts since the widespread advent of ultrasound into clinical practice. The ability to access hitherto inaccessible nerves and fascial planes in the human body whilst ensuring visualisation of the needle tip during block performance has opened the proverbial floodgates leading to its widespread adoption, further supported by a growing body of evidence for its many benefits in a patient's perioperative journey and pain management. The concomitant advancement of technology and the development of powerful simulation and artificial intelligence tools has given a much-needed impetus towards improving training and safe practice in regional anaesthesia.
View Article and Find Full Text PDFSensors (Basel)
January 2025
University-Industrial Cooperation Corps of HiVE Center, Wonkwang Health Science University, 514, Iksan-daero, Iksan-si 54538, Republic of Korea.
Virtual reality (VR) technology has gained popularity across various fields; however, its use often induces cybersickness, characterized by symptoms such as dizziness, nausea, and eye strain. This study investigated the differences in cybersickness levels and head movement patterns under three distinct VR viewing conditions: dynamic VR (DVR), static VR (SVR), and a control condition (CON) using a simulator. Thirty healthy adults participated, and their head movements were recorded using the Meta Quest 2 VR headset and analyzed using Python.
View Article and Find Full Text PDFSensors (Basel)
January 2025
College of Transportation, Shandong University of Science and Technology, Qingdao 266590, China.
To address the problems that exist in the target detection of vehicle-mounted visual sensors in foggy environments, a vehicle target detection method based on an improved YOLOX network is proposed. Firstly, to address the issue of vehicle target feature loss in foggy traffic scene images, specific characteristics of fog-affected imagery are integrated into the network training process. This not only augments the training data but also improves the robustness of the network in foggy environments.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!