Purpose: Orthokeratology (OK) is known to alter relative peripheral refraction (RPR) with this presumed to be its key myopia control mechanism. A prospective, longitudinal study was performed to examine stability of OK-induced RPR changes in myopic children and young adults.
Methods: RPR of twelve children (C)(8-16 years) and eight adults (A)(18-29 years) with spherical equivalent refraction of -0.75 to -5.00D were measured unaided and while wearing single vision soft contact lenses (SCL). Measurements were repeated after 1, 6 and 12 months of OK wear. RPR was measured using an open-field Shin Nippon SRW-5000 autorefractor at 10, 20 and 30 degrees nasally (N) and temporally (T), converted into power vectors M, J0 and J45. On-axis refractions and axial lengths (IOL Master) were also measured.
Results: Compared to the unaided state, 1-month of OK wear shifted the RPR in the myopic direction at 30 T (C: p = 0.023; A:, p = 0.002) and 30 N (C&A, p = 0.003) and was stable thereafter, with similar changes compared to SCL wear. J0 showed a myopic shift in comparison to both unaided and SCL correction in children but not adults, and J45 did not change in either group. The on-axis OK correction was predictive of the RPR shift in both children and adults at 30 T (C: r=-0.58, p = 0.029; A: r=-0.92, p < 0.001) and 30 N (C: r=-0.60, p = 0.024; A: r=-0.74, p = 0.013) with symmetry of RPR shifts (C: r = 0.67, p = 0.008; A: r = 0.85, p = 0.004). No relationships between changes in RPR and axial length were found after twelve months of OK wear; level of myopia was stable in both groups.
Conclusion: Relative to both unaided and single vision SCL correction, OK shifted the RPR in the myopic direction; the RPR was stable from 1 to 12 months. The RPR shift in OK wear varied with the degree of myopia but was not correlated with myopia progression.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.clae.2019.11.008 | DOI Listing |
Purpose: To evaluate dynamic changes in ciliary parameters and Implantable Collamer Lens V4C (ICL) (STAAR Surgical) haptic position using mydriatic and miotic agents and their effects on the central and peripheral vault.
Methods: This study involved 80 eyes from 40 consecutive patients (mean age: 28.05 years; range: 19 to 42 years) examined 3 months after ICL implantation.
Graefes Arch Clin Exp Ophthalmol
December 2024
Eye Ear Nose and Throat Hospital, Fudan University, XuHui District, No. 19 BaoQing Road, Shanghai, 200031, China.
Purpose: This study aimed to measure the changes in refraction difference value (RDV) in different parts of the retina before and after implantable collamer lenses (ICL) surgery.
Design: Prospective study.
Methods: This study included 40 eyes of 40 patients who underwent ICL implantation for myopia.
Indian J Ophthalmol
December 2024
Cornea, Cataract and Refractive Surgery Services, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
Intrascleral haptic fixation of intraocular lens (IOL) is an extremely useful technique to provide visual rehabilitation in eyes with inadequate capsular support. It requires exteriorization of haptics along with tucking of haptics in the scleral groove preferably and conventionally in the horizontal meridian. In eyes with large corneal diameter, there is difficulty in tucking enough length of the haptics into the intrascleral groove, carrying the risk of slippage of haptics and decentration of IOL.
View Article and Find Full Text PDFFront Neurosci
December 2024
School of Optometry, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, China.
Purpose: This study evaluates differences in the visual field performance when wearing the Defocus Incorporated Multiple Segments (DIMS) spectacle lens compared to wearing a conventional single vision (SV) spectacle lens.
Methods: Twenty-one children aged 9-14 years with spherical equivalent refraction (SER) between -1.13D to -4.
Front Med (Lausanne)
December 2024
Department of Biopharmaceutics and Clinical Pharmacy, School of Pharmacy, The University of Jordan, Amman, Jordan.
This study investigated how normal corneal stromal profiles change with age, sex, and corrected intraocular pressure (IOP). A retrospective observational analytical study was conducted in Jordan, employing anterior segment spectral-domain optical coherence tomography AS-OCT, a measured corneal stromal thickness (CST) in 134 eyes across the central 6-mm corneal diameter. People between the ages of 18 and 79 were included, and the mean CST values were linked to age groups, IOP, and cis-gender populations, with the exclusion of certain eye conditions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!