Managing severe valvular heart disease with mechanical valve replacement necessitates lifelong anticoagulation with a vitamin K antagonist. Optimal anticoagulation intensity for patients with mechanical valves remains uncertain; current recommendations are inconsistent across guideline bodies and largely based on expert opinion. In this review, we outline the history of anticoagulation therapy in patients with mechanical heart valves and critically evaluate current antithrombotic guidelines for these patients. We conclude that randomized trials evaluating optimal anticoagulation intensity in patients with mechanical valves are needed, and that future guidelines must better justify antithrombotic treatment recommendations.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCULATIONAHA.119.041105DOI Listing

Publication Analysis

Top Keywords

patients mechanical
12
anticoagulation therapy
8
mechanical valve
8
valve replacement
8
optimal anticoagulation
8
anticoagulation intensity
8
intensity patients
8
mechanical valves
8
anticoagulation
5
mechanical
5

Similar Publications

Pelvic packing - status 2024.

Arch Orthop Trauma Surg

January 2025

Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway.

Patients with unstable hemodynamics and unstable pelvic ring injuries are still demanding patients regarding initial treatment and survival. Several concepts were reported during the last 30 years. Mechanical stabilization of the pelvis together with hemorrhage control offer the best treatment option in these patients.

View Article and Find Full Text PDF

Safety of accessing brachial veins for large-bore upper extremity venous thrombectomy using ClotTriever Thrombectomy System.

CVIR Endovasc

January 2025

Department of Radiology, Section of Vascular and Interventional Radiology, University of Washington, 1959 Northeast Pacific Street, Seattle, WA, 98195, USA.

Purpose: To evaluate access site adverse events following ClotTriever-mediated large-bore mechanical thrombectomy via small upper extremity deep veins (< 6-mm).

Materials And Methods: Twenty patients, including 24 upper extremity venous access sites, underwent ClotTriever-mediated large-bore thrombectomy of the upper extremity and thoracic central veins for symptomatic deep vein obstruction unresponsive to anticoagulation. Patients without follow-up venous duplex examinations (n = 3) were excluded.

View Article and Find Full Text PDF

Mechanical analysis of cerclage as a treatment for cervical insufficiency.

Arch Gynecol Obstet

January 2025

Department of Obstetrics and Gynecology, Ulsan University Hospital, University of Ulsan, College of Medicine, 25 Daehakbyeongwon-ro, Dong-gu, Ulsan, 44033, South Korea.

Background: The primary treatment for cervical insufficiency is cervical cerclage (mechanical support) with vaginal progesterone (biochemical support). Cerclage is a surgical procedure that mechanically increases the tensile capacity of the cervix. Therefore, it is necessary to analyse the effects of cerclage from a mechanical point of view.

View Article and Find Full Text PDF

Finite model analysis of different anchorage sites for bone-supported facemask application in unilateral cleft lip and palate.

Am J Orthod Dentofacial Orthop

January 2025

Department of Orthodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkey. Electronic address:

Introduction: The objective of this study was to evaluate the effects of the miniplate application sites in the maxilla and the applied force vector changes during skeletally supported facemask application in adolescent patients with unilateral cleft lip and palate (UCLP) using finite element model (FEM) analysis.

Methods: A FEM was obtained from a cone-beam computed tomography image of a 12-year-old female patient with UCLP. Miniplates were placed on 3 different sites of the maxilla; 500 g of advancement force was applied bilaterally, parallel (0°), and downward (-30°) to the occlusal plane.

View Article and Find Full Text PDF

Fiber-based strain sensors, as wearable integrated devices, have shown substantial promise in health monitoring. However, current sensors suffer from limited tunability in sensing performance, constraining their adaptability to diverse human motions. Drawing inspiration from the structure of the spiranthes sinensis, this study introduces a unique textile wrapping technique to coil flexible silver (Ag) yarn around the surface of multifilament elastic polyurethane (PU), thereby constructing a helical structure fiber-based strain sensor.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!