  • The hemoglobin content in blood is a key health indicator, with abnormal presence in fluids like plasma or urine indicating diseases such as hemolytic anemia or urinary tract infections.
  • A novel assay method employs hemoglobin-catalyzed atom transfer radical polymerization (ATRP) to quantify hemoglobin via turbidity, allowing detection of very low concentrations in various body fluids.
  • This polymerization-based approach is safer and more environmentally friendly than traditional tests, which often use toxic chemicals, making it a better option for clinical labs and point-of-care diagnostics.

Article Abstract

The hemoglobin content of blood is an important health indicator, and the presence of microscopic amounts of hemoglobin in places where it normally does not occur, e.g. in blood plasma or in urine, is a sign of diseases such as hemolytic anemia or urinary tract infections. Thus, methods to detect and quantify hemoglobin are important for clinical laboratories, blood banks, and for point-of-care diagnostics. The precipitation polymerization of -isopropylacrylamide by hemoglobin-catalyzed atom transfer radical polymerization (ATRP) is used as an assay for hemoglobin quantification relying on the formation of turbidity as a simple optical read-out. Dose-response curves for pure hemoglobin and for hemoglobin in blood plasma, in urine, in erythrocytes, and in full blood are obtained. Turbidity formation increases with the concentration of hemoglobin. Concentrations of hemoglobin as low as 6.45 × 10 mg mL in solution, 4.88 × 10 mg mL in plasma, and 1.65 × 10 mg mL in urine could be detected, which is below the clinically relevant concentrations in the respective body fluids. Total hemoglobin in full blood is also accurately determined. The reaction can be regarded as a polymerization-based signal amplification for the sensing of hemoglobin, as the analyte catalyzes the formation of radicals which add many monomer units into detectable polymer chains. While most established hemoglobin tests involve the use of highly toxic reagents such as potassium cyanide, the polymerization-based test uses simple and stable organic reagents. Thus, it is an environmentally friendlier alternative to established chemical assays for hemoglobin.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.9b04290DOI Listing

Publication Analysis

Top Keywords

hemoglobin
13
atom transfer
8
transfer radical
8
radical polymerization
8
polymerization atrp
8
blood plasma
8
plasma urine
8
full blood
8
blood
6
biocatalytically initiated
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!