Background: In the event of a surgical site infection, management includes surgical debridement in an attempt to treat the infection and retain the implant; however they are often unsuccessful in this regard. Although studies have described the incidence of complications, current literature does not have sufficient evidence to provide clear recommendations regarding retention versus removal of implants. This study aims to identify predictive factors associated with the need for implant removal to decrease unnecessary attempts at implant retention.
Methods: A retrospective review of early-onset scoliosis patients at a single institution treated with rib-based vertical expandable prosthetic titanium rib implants who developed infection requiring irrigation and debridement (I&D) due to wound problems including surgical site infection, skin slough, and wound dehiscence. All patients had a minimum of a 2-year follow-up. Univariate and multivariate logistic regression analyses were conducted to determine the odds of implant removal.
Results: Fifty-nine of 181 patients (32%) required an I&D due to a wound problem. These patients underwent the initial implant procedure at a mean age of 4.6±3.8 years. In total, 29 patients ultimately underwent implant removal. Significant predictive factors for removal included total number of wound problems, total number of I&Ds, days from identification of wound problem to I&D procedure, days on antibiotics, total number of surgeries, presence of gastrostomy tube, and nonambulatory status (P<0.0001, 0.001, 0.095, 0.093, 0.082, 0.054, and 0.026, respectively). Multiple logistic regression results indicated a total number of wound problems [odds ratio (OR): 6.00, P=0.001], average days from identification of wound problem to I&D (OR: 1.03, P=0.039), and presence of a gastrostomy tube (OR: 5.7, P=0.07) as independent predictors for implant removal.
Conclusions: Data suggests that time from the onset of signs of infection until debridement surgery inversely correlates with the ability to retain the implants. In addition, gastrostomy tube and history of previous wound infections may be predictive clinical factors for implant removal in patients with a rib-based vertical expandable prosthetic titanium rib instrumentation. Such information can be useful for clinicians in deciding on whom to attempt implant retention versus removal when a wound problem presents itself.
Level Of Evidence: Level III.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BPO.0000000000001475 | DOI Listing |
J AAPOS
January 2025
Johns Hopkins University Wilmer Eye Institute, Baltimore, Maryland. Electronic address:
Background Recommendations regarding long-term postoperative activity are intended to prevent adverse events, but no common policy or best practice exists among ophthalmologists for pediatric patients. We surveyed ophthalmologists on their postoperative guidelines after the one-month postoperative period following childhood cataract and glaucoma surgeries. Methods A 28-question anonymous Qualtrics survey was distributed via listservs and social media.
View Article and Find Full Text PDFPharmaceutics
January 2025
Division of Clinical Pharmacology, Department of Medicine, School of Medicine, The Johns Hopkins University, Baltimore, MD 21287, USA.
Long-acting and extended-release drug delivery strategies have greatly improved treatment for a variety of medical conditions. Special populations, specifically infants, children, young people, and pregnant and postpartum women, could greatly benefit from access to these strategies but are often excluded from clinical trials. We conducted a systematic review of all clinical studies involving the use of a long-acting intramuscular injection or implant in infants, children, young people, and pregnant and postpartum people.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Periodontology and Oral Mucosa Diseases, Medical University of Warsaw, Binieckiego 6 St., 02-097 Warsaw, Poland.
: The aim of the present narrative review is to synthesize the available scientific evidence on the effects of submarginal instrumentation with periodontal endoscopy and evaluate its' potential efficacy in terms of the non-surgical therapy of peri-implantitis. : The literature search was performed via electronic databases, including PubMed, Web of Science, Cochrane, and Scopus, and was supplemented by manual searching. A literature review was conducted addressing the following PICOS questions: (1) What is the efficacy of non-surgical submarginal instrumentation of the implant surface with the aid of a periodontal endoscope in patients with peri-implantitis? (2) What is the efficacy of non-surgical subgingival instrumentation performed with the aid of a periodontal endoscope compared with conventional subgingival instrumentation in patients with periodontitis, in terms of clinical parameters and patient-reported outcomes? Mechanical decontamination of the implant surface is crucial for resolving inflammation and arresting further bone loss.
View Article and Find Full Text PDFMolecules
January 2025
Yunnan Key Laboratory of Metal-Organic Molecular Materials and Device, Kunming University, Kunming 650214, China.
A covalent organic framework (COF) has emerged as a promising photocatalyst for the removal of pharmaceutical and personal care product (PPCP) contaminants; however, high-performance COF photocatalysts are still scarce. In this study, three COF photocatalysts were successfully synthesized by the condensation of benzo[1,2-b:3,4-b':5,6-b'']trithiophene-2,5,8-tricarbaldehyde (BTT) with 4,4',4''-(1,3,5-triazine-2,4,6-triyl)trianiline (TAPT), 1,3,5-Tris(4-aminophenyl)benzene (TAPB), and 4,4',4''-nitrilotris(benzenamine) (TAPA), namely, BTT-TAPA, BTT-TAPB, and BTT-TAPT, respectively. The surface areas of BTT-TAPA, BTT-TAPB, and BTT-TAPT were found to be 800.
View Article and Find Full Text PDFMaterials (Basel)
January 2025
King Abdulaziz City for Science and Technology (KACST), Microelectronics and Semiconductors Institute, Mailbox 6086, Riyadh 11442, Saudi Arabia.
With growing environmental concerns and the need for sustainable energy, multifunctional materials that can simultaneously address water treatment and clean energy production are in high demand. In this study, we developed a cost-effective method to synthesize zinc oxide (ZnO) nanowires via the anodic oxidation of zinc foil. By carefully controlling the anodization time, we optimized the Zn/ZnO-5 min electrode to achieve impressive dual-function performance in terms of effective photoelectrocatalysis for water splitting and waste water treatment.