Evaluation of sample stability for cellular kinetics and pharmacodynamic flow cytometry methods.

Bioanalysis

Biomarker Laboratories, PPD, Richmond, VA 23230, USA.

Published: October 2019

We evaluated the sample stability for a cellular kinetics and a pharmacodynamic flow cytometry methods. First, the blood collection tubes were compared for the enumeration of chimeric antigen receptor-T cells in human whole blood. Blood samples with chimeric antigen receptor-T cells were stable up to 3 days at room temperature in both conventional EDTA and Cyto-Chex blood collection tubes (Streck Laboratories, NE, USA), but with better consistency in Cyto-Chex-BCT than conventional EDTA tubes. Second, sample storage temperatures were compared for the basophil activation test in human whole blood samples. The samples were stable up to 3 days for basophil activation test when stored at refrigerator temperature, but not stable when stored at room temperature. It is crucial during the development of method to evaluate all the variables which might impact sample integrity.

Download full-text PDF

Source
http://dx.doi.org/10.4155/bio-2019-0170DOI Listing

Publication Analysis

Top Keywords

sample stability
8
stability cellular
8
cellular kinetics
8
kinetics pharmacodynamic
8
pharmacodynamic flow
8
flow cytometry
8
cytometry methods
8
blood collection
8
chimeric antigen
8
antigen receptor-t
8

Similar Publications

Background: A goal of mucosal human immunodeficiency virus type 1 (HIV-1) vaccines is to generate mucosal plasma cells producing polymeric IgA (pIgA)-neutralizing antibodies at sites of viral entry. However, vaccine immunogens capable of eliciting IgA neutralizing antibodies (nAbs) that recognize tier 2 viral isolates have not yet been identified.

Methods: To determine if stabilized native-like HIV-1 envelope (Env) trimers could generate IgA nAbs, we purified total IgA and IgG from the banked sera of six rhesus macaques that had been found in a previous study to develop serum nAbs after subcutaneous immunization with BG505.

View Article and Find Full Text PDF

Dynamics of PCV2 and PCV3 in the Serum and Oral Fluids of Pigs After PCV2 Vaccination in a Commercial Farm.

Vaccines (Basel)

November 2024

Department of Veterinary Diagnosis and Production Animal Medicine, College of Veterinary Medicine, Iowa State University, Ames, IA 50011, USA.

Objectives: This study investigated the dynamics of porcine circovirus type 2 (PCV2) and PCV3 on a commercial farm following PCV2 vaccination.

Methods: Serum samples from 35 pigs, starting at 3 weeks of age, were collected weekly until 21 weeks of age. Oral fluids from six pens of pigs of the same age were also analyzed.

View Article and Find Full Text PDF

: The global COVID-19 pandemic has resulted in approximately 7 million deaths and a historic vaccination effort, with over 13.6 billion doses administered. Despite this, understanding of immune responses in vulnerable populations, such as transplant recipients (TR) and hemodialysis patients (HD), remains limited, especially outside the US and Europe.

View Article and Find Full Text PDF

Lane Detection Based on ECBAM_ASPP Model.

Sensors (Basel)

December 2024

School of Artificial Intelligence and Computer Science, Nantong University, Nantong 226019, China.

With the growing prominence of autonomous driving, the demand for accurate and efficient lane detection has increased significantly. Beyond ensuring accuracy, achieving high detection speed is crucial to maintaining real-time performance, stability, and safety. To address this challenge, this study proposes the ECBAM_ASPP model, which integrates the Efficient Convolutional Block Attention Module (ECBAM) with the Atrous Spatial Pyramid Pooling (ASPP) module.

View Article and Find Full Text PDF

This work presents the development of an amperometric biosensor for detecting aspartate aminotransferase (AST) activity in biological fluids using a platinum disk electrode as the working transducer. Optimal concentrations of substrates (aspartate, α-ketoglutarate) and the coenzyme (pyridoxal phosphate) were determined to ensure efficient biosensor operation. A semi-permeable poly-m-phenylenediamine membrane was applied to enhance selectivity against electroactive interferents.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!