Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Stress shielding may lead to aseptic loosening which is a common reason for implant failure. An established method to identify implants with risk of implant failure caused by aseptic loosening is to measure early migration of the stem with the "Ein Bild Roentgen Analyse" femoral component analysis (EBRA-FCA). Therefore, the aim of this study was to measure the migration of a cementless short stem prosthesis via EBRA-FCA to predict the future performance.
Materials And Methods: A total collective of 71 patients were treated with a cementless short hip stem prosthesis. Indications for surgery were primary coxarthrosis, dysplasia coxarthrosis or femoral head necrosis. After surgery, the patients were followed-up immediately after 3, 6, 12, 24, 36, and 48 months and X-ray images for EBRA-FCA measurements were taken. Axial caudal migration as well as the varus/valgus tilting of the prosthesis was determined. Possible influencing factors like BMI, age, diagnosis, gender or Harris Hip Score (HHS) on the migration of the stem were assessed.
Results: HHS increased significantly direct postoperatively (p < 0.001). At the second follow-up the average caudal migration was 0.42 ± 0.52 mm (range: 0.00-2.85 mm) (p < 0.001). A total of 14 patients underwent a caudal migration greater than 1.5 mm until 48 months. The initial varus and valgus tilts within the first 3 months were significant (p < 0.001). No correlations between BMI, age, diagnosis, gender or HHS and the migration as well as the tilting of the cementless short hip stem prosthesis were found.
Conclusions: Although initial axial caudal migration as well as tilting tendencies in varus or valgus position can be detected, there is no marked migration of the examined prosthesis after the first 48 months. Likewise, no aseptic early loosening was detected throughout the study period, which indicates good osseointegration of the short stem prosthesis.