Introduction: Cranioplasty in children is a controversial and challenging issue, since there is still no consensus on the ideal material. Main problems in paediatric age are represented by the child's growing skull, the lower bone thickness and the high incidence of cerebrospinal fluid (CSF) disorders or brain swelling. Autologous bone is still considered the "gold standard". When it is not available, a wide range of alloplastic materials have been proposed. Hydroxyapatite, a ceramic-based derivative, bears a chemical composition very similar to the human natural bone, making this material a valuable alternative to other cranioplasty solutions.
Methods: All patients implanted with a custom-made porous hydroxyapatite device at Santobono-Pausilipon Hospital in Naples were retrospectively reviewed. A follow-up CT scan of the skull was performed from 1 up to 48 months postoperatively to document the bone ingrowth as well as the osteointegration process. The bone density was measured as according to the Hounsfield scale at the bone-implant interface.
Results: Between 2014 and 2018, 11 patients (7 males, 4 females) underwent cranioplasty with hydroxyapatite ceramic implants (HAP). Patients' age ranged between 3 and 16 years old. Initial aetiology was trauma in most cases. Two subjects were implanted with HAP as primary cranioplasty, 9 as revision surgery following previous cranioplasty failure. Sites of the cranial defect were unilateral fronto-temporo-parietal (N = 8), unilateral frontal (N = 1) and bifrontal (N = 2). Two patients with large bilateral defects received two prostheses. In one of these, the two prostheses were explanted and replaced with two back-up implants (accounting for a total of 15 implants in 11 patients). Osteointegration was measurable for 12 out of 15 implanted devices. The mean percentage was about 51%. There were six asymptomatic prosthesis fractures (40%), all occurring within 6 months from implant. In one case, the bifrontal prostheses were explanted and replaced. This was the only patient who underwent revision surgery.
Conclusion: Hydroxyapatite ceramic implants represent a valid alternative to other cranioplasty solutions. Where coaptation occurs correctly, with good osteointegration, implant mechanical resistance increases over time.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00381-019-04423-6 | DOI Listing |
Biomed Mater
January 2025
Chemistry, Manipal University Jaipur, Jaipur, Jaipur, 303007, INDIA.
Hydroxyapatite (HAP) nano-coatings on titanium alloys (for example, Ti6Al4V) have been used for prosthetic orthopedic implants in recent decades due to their osseointegration, bioactivity, and biocompatibility. HAP is brittle with low mechanical strength and poor adhesion on metallic surfaces, which limits its durability and bioactivity. Surface modification techniques have alleviated the imperfection of biomaterials by coating the substrate.
View Article and Find Full Text PDFSci Rep
January 2025
SANKEN, Osaka University, 8-1 Mihogaoka, Ibaraki, 567-0047, Osaka, Japan.
Hydroxyapatite/zirconia (HAP/ZrO) composites were fabricated via the low-temperature mineralization sintering process (LMSP) at an extremely low temperature of 130 °C to enhance the mechanical properties of HAP and broaden its practical applications. For this purpose, 5-20 vol% calcia-stabilized ZrO were introduced into HAP, and HAP/ZrO nanoparticles, mixed with simulated body fluid, were densified under a uniaxial pressure of 800 MPa at 130 °C. At 10 vol% ZrO, the relative density of the HAP/ZrO composite was determined to be 88.
View Article and Find Full Text PDFSci Rep
January 2025
Physics Department, Faculty of Science, Al-Azhar University, Nasr City, Cairo, 11884, Egypt.
This study aims to synthesize a new localized drug delivery system of bioglass, polyvinyl alcohol (PVA), cellulose (CNC), and sodium alginate (SA) beads as a carrier for methotrexate (MTX) drugs for the treatment of osteosarcoma. Methotrexate /Bioglass-loaded Polyvinyl/Cellulose/Sodium alginate biocomposite beads were prepared via the dropwise method with different concentrations of (65%SiO-30%CaO- 5%PO) bioglass. Samples were named B0, S0, S1, S2, and S3, respectively.
View Article and Find Full Text PDFJ Spine Surg
December 2024
Department of Neurosurgery, The Gemelli University Hospital, Rome, Italy.
Background: Aneurysmal bone cysts (ABCs) are benign, blood-filled neoplasms causing bone destruction, often requiring resection. However, challenges arise, especially at the cranio-cervical junction, where proximity to critical structures limits removal. Non-surgical options include selective arterial embolization (SAE) as main treatment, while Denosumab and centrifugated bone marrow emerge as experimental alternatives.
View Article and Find Full Text PDFJ Spine Surg
December 2024
Orthopedic Associates of Hartford, Hartford Hospital Bone and Joint Institute, Hartford, CT, USA.
Background And Objective: As the global population ages, degenerative spinal disorders are on the rise, leading to an increased focus on optimizing spinal fusion therapies. Despite the high success rate of iliac crest bone autografts, their usage is hampered by donor site morbidity and limited supply. The objective of this review is to assess the viability of ceramic-based synthetic materials as alternatives in spinal fusion surgeries.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!