Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Arsenic field test kits are widely used to measure arsenic levels in drinking water sources, especially in countries like Bangladesh, where water supply is highly decentralized and water quality testing infrastructure is limited. From a public health perspective, the ability of a measurement technique to distinguish samples above and below relevant and actionable drinking water standards is paramount. In this study, the performance of eight commercially available field test kits was assessed by comparing kit estimates to hydride generation atomic absorption spectroscopy (HG-AAS) analyses. The results of tests that control for user-dependent color matching errors showed that two kits (LaMotte and Quick II kits) provided accurate and precise estimates of arsenic, four kits (Econo-Quick, Quick, Wagtech and Merck kits) were either accurate or precise, but not both, and two kits (Hach and Econo-Quick II kits) were neither accurate nor precise. Tests were performed for arsenic concentration ranges commonly found in natural waters and treated waters (such as community drinking water filter systems), and also on laboratory generated arsenic standards in DI water. For those kits that did not perform well, test strips often produced colors too light compared to manufacturer-provided arsenic color calibration charts. Based on these results, we recommend stakeholders carefully re-consider the use of poorly performing field test kits until better quality control of components of these kits is implemented. In addition, we recommend that field test kit manufacturers provide suitable internal standards in every kit box for users to verify the veracity of manufacturer provided color charts.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.watres.2019.115325 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!