A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Long-Term Home-Monitoring Sensor Technology in Patients with Parkinson's Disease-Acceptance and Adherence. | LitMetric

Parkinson's disease (PD) is characterized by a highly individual disease-profile as well as fluctuating symptoms. Consequently, 24-h home monitoring in a real-world environment would be an ideal solution for precise symptom diagnostics. In recent years, small lightweight sensors which have assisted in objective, reliable analysis of motor symptoms have attracted a lot of attention. While technical advances are important, patient acceptance of such new systems is just as crucial to increase long-term adherence. So far, there has been a lack of long-term evaluations of PD-patient sensor adherence and acceptance. In a pilot study of PD patients (N = 4), adherence (wearing time) and acceptance (questionnaires) of a multi-part sensor set was evaluated over a 4-week timespan. The evaluated sensor set consisted of 3 body-worn sensors and 7 at-home installed ambient sensors. After one month of continuous monitoring, the overall system usability scale (SUS)-questionnaire score was 71.5%, with an average acceptance score of 87% for the body-worn sensors and 100% for the ambient sensors. On average, sensors were worn 15 h and 4 min per day. All patients reported strong preferences of the sensor set over manual self-reporting methods. Our results coincide with measured high adherence and acceptance rate of similar short-term studies and extend them to long-term monitoring.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6928790PMC
http://dx.doi.org/10.3390/s19235169DOI Listing

Publication Analysis

Top Keywords

sensor set
12
adherence acceptance
8
body-worn sensors
8
ambient sensors
8
sensors
6
sensor
5
adherence
5
acceptance
5
long-term
4
long-term home-monitoring
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!