This paper describes a compact microfluidic analytical device developed for the detection of low airborne formaldehyde concentrations. This microdevice was based on a three-step analysis, i.e., the passive gaseous formaldehyde uptake using a microporous membrane into an acetylacetone solution, the derivatization with acetylacetone to form 3,5-diacetyl-1,4-dihydrolutidine, and the quantification of the latter using fluorescence detection. For a rapid and easier implementation, a cylindrical geometry of the microporous element was considered to perform laboratory-controlled experiments with known formaldehyde concentrations and to establish the proof of concept. This work reports the evaluation of the uptake performance according to the microporous tube length, the liquid flow rate inside the tube, the gas flow rate outside the tube, and the gaseous formaldehyde concentration. A 10.0 cm microporous tube combined with a gas flow rate of 250 NmL/min (normal milliliters per minute) and a liquid flow rate of 17 µL/min were found to be the optimized conditions. In these experimental conditions, the fluorescence signal increased linearly with the gaseous formaldehyde concentration in the range 0-118 µg/m, with the detection limit being estimated as 0.13 µg/m when considering a signal-to-noise ratio of 3.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6952779PMC
http://dx.doi.org/10.3390/mi10120807DOI Listing

Publication Analysis

Top Keywords

flow rate
16
microporous tube
12
gaseous formaldehyde
12
airborne formaldehyde
8
microfluidic analytical
8
analytical device
8
uptake microporous
8
formaldehyde concentrations
8
liquid flow
8
gas flow
8

Similar Publications

Introduction: During hemodialysis (HD), the presence of clots in the dialyzer can diminish the effective surface area of the device. In severe cases, clot formation in the circuit can halt treatment and lead to blood loss in the system. Thus, ensuring proper anticoagulation during HD is crucial to prevent clotting in the circuit while safeguarding the patient from bleeding risks.

View Article and Find Full Text PDF

Background: The stent-assisted coiling (SAC) and flow-diverter stent (FDS) techniques are widely used in the endovascular treatment of paraclinoid aneurysms. This article compares the occlusion rate, periprocedural complications, and clinical outcomes of SAC and FDSs.

Methods: Between January 2010 and December 2020, a systematic search of electronic databases identified 2283 articles for screening.

View Article and Find Full Text PDF

The role of autophagy related 12 (ATG12) in the progression of hepatocellular carcinoma and its prognostic value.

Discov Oncol

December 2024

Department of Hospital Infection Management, Zhongshan Hospital Qingpu Branch, Fudan University, Shanghai, 201700, China.

The aim of our research was to explore the character of autophagy related 12 (ATG12) in the development of hepatocellular carcinoma (HCC). A total of  145 HCC tissues as well as paired adjacent normal tissues were collected, then immunohistochemistry was conducted to access the expression of ATG12. HCC cells were transfected with pcDNA ATG12 or si-ATG12 to overexpress ATG12 or downregulate ATG12.

View Article and Find Full Text PDF

Objective: In recent years, the application of robotic assistance in diagnostic and therapeutic endovascular neurointerventional procedures has gained notable attention. In this systematic review and meta-analysis, we aim to evaluate the feasibility, safety, and current indications of robotic-assisted neurointerventions and to assess the degree of robotic assistance and reasons for unplanned manual conversion from robotic assistance.

Methods: We searched Medline, Scopus, Web of Science, and Cochrane Library databases following PRISMA guidelines and included studies with ≥ 4 patients reporting on robotic-assisted neurointerventions.

View Article and Find Full Text PDF

There is scant information available about the blood flow of the pulmonary artery in avian cardiology. In human medicine, the shape of the Doppler sonographic blood flow profile of the pulmonary artery can be used to access the pressure conditions of the right heart. With this background, this study focused on the examination of the acceleration and deceleration phase of the pulsed-wave Doppler flow profile of the pulmonary artery of healthy racing pigeons.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!