Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This study was conducted to test an automated method to identify unknown individuals. It relies on a previous radiographic file and uses an edge-based comparison of lumbar CT/PMCT reconstructions and radiographs. The living group was composed of 15 clinical lumbar spine CT scans and 15 paired radiographs belonging to the same patients. The deceased group consisted of 5 lumbar spine PMCT scans and 5 paired antemortem radiographs of deceased individuals plus the 15 unpaired radiographs belonging to the living. An automated method using image filtering (anisotropic diffusion) and edge detection (Canny filter) provided image contours. Cross comparisons of all the exams in each group were performed using similarity measurements under the affine registration hypothesis. The Dice coefficient and Hausdorff distance values were significantly linked (p < 0.001 and p = 0.001 respectively) to the matched examinations in the living group (p < 0.001; pseudo-R2 = 0.70). 12 of the 15 examinations were correctly paired, 2 were wrongly paired and 3 were not paired when they must have been. In the deceased group, the Hausdorff distance was significantly linked (p = 0.018) to the matched examinations (p < 0.001; pseudo-R2 = 0.62; Dice coefficient p = 0.138). The paired examinations were all correctly found, but one was wrongly paired. The negative predictive value was above 98% for both groups. We highlighted the feasibility of comparative radiological identification using automated edge detection in cross-modality (CT/PMCT scan and radiographs) examinations. This method could be of significant help to a radiologist or coroner in identifying unknown cadavers.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s12024-019-00189-0 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!