Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: The objective of this quality improvement (QI) project was to decrease the rate of low-value computed tomography (CT) imaging in established gynecologic oncology patients presenting to the emergency department (ED).
Methods: This was a cohort study with a before and after design that evaluated implementation of a QI project designed to decrease CT utilization in established gynecologic oncology patients in the ED. The pre-intervention cohort included patients admitted through the ED from 4/1/17 to 5/31/18, while the post-intervention cohort was from 6/1/18 to 5/31/19. The intervention included gynecologic oncology consultation before CT on patients who had imaging within the prior 3 weeks. Details regarding CT, ED length of stay (LOS), and oncologic history were abstracted. The value of CT was determined by consensus from 2 reviewers. Prospective data monitoring evaluated for patient safety.
Results: Prior to intervention, there were 129 unique ED encounters in gynecologic oncology patients leading to admission. CT scans were performed in 101 (78.3%) encounters, 57.7% of which were deemed to be of low-value. Following implementation, the CT utilization rate decreased significantly from median monthly rate of 75.2% to 49.1% (p < 0.00001), and the ED LOS decreased from 8.1 to 6.9 h (p = 0.0102). The number of CT scans deemed to be low-value in the post-intervention group decreased to 2 (3.8%).
Conclusions: Implementation of an early consultation policy and imaging guidelines led to a significant decrease in unnecessary CT utilization and shorter ED LOS in gynecologic oncology patients presenting to the ED.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ygyno.2019.11.024 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!