The effect of equal-channel angular pressing (ECAP) on the microstructure, texture, mechanical properties, corrosion resistance and cytotoxicity of two magnesium-silver alloys, Mg-2.0%Ag and Mg-4.0%Ag, was studied. Their average grain size was found to be reduced to 3.2 ± 1.4 μm and 2.8 ± 1.3 μm, respectively. Despite the substantial grain refinement, a drop in the strength characteristics of the alloys was observed, which can be attributed to the formation of inclined basal texture. On a positive side, an increase in tensile ductility to ~34% for Mg-2.0%Ag and ~27% for Mg-4.0%Ag was observed. This effect can be associated with the activity of basal and prismatic slip induced by ECAP. One of the ECAP regimes tested gave rise to a drop in the corrosion resistance of both alloys. An interesting observation was a cytotoxic effect both alloys had on tumor cells in vitro. This effect was accompanied with the release of lactate dehydrogenase, an increase in oxidative stress, coupled with the induction of NO-ions and an increase in the content of such markers of apoptosis as Annexin V and Caspase 3/7. Differences in the chemical composition and the processing history-dependent microstructure of the alloys did not have any significant effect on the magnitude of their antiproliferative effect.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6926692 | PMC |
http://dx.doi.org/10.3390/ma12233832 | DOI Listing |
Biomed Mater
December 2024
State Key Laboratory of Nuclear Physics and Technology, Department of Technical Physics, School of Physics, Peking University, Beijing 100871, People's Republic of China.
Titanium (Ti), characterized by its exceptional mechanical properties, commendable corrosion resistance and biocompatibility, has emerged as the principal functional materials for implants in biomedical and clinical applications. However, the Ti-6Al-4V (TC4ELI) alloy has cytotoxicity risks, whereas the strength of the existing industrially pure titanium TA4 is marginally inadequate and will significantly limit the scenarios of medical implants. Herein, we prepared ultrafine-grained industrial-grade pure titanium TA4 and titanium alloy TC4ELI via the equal channel angular pressing method, in which the TA4-1 sample has ultrahigh strength of 1.
View Article and Find Full Text PDFActa Biomater
December 2024
School of Mechanical and Mining Engineering, University of Queensland, Brisbane QLD4072, Australia.
The significance of biomedical applications of bio-functional niobium (Nb)-based metallic biomaterials is underscored by their potential utilization in implant application. Nb-based metallic materials present reliable physicomechanical and biological properties, thus represent materials highly suitable for implant application. This review provides an overview on the advances of pure niobium and Nb-based metallic materials as implant materials over the past 20 years, and highlights the advantages of Nb-based metallic biomaterials for implant application in terms of their physicomechanical properties, corrosion resistance in biological media, magnetic resonance imaging (MRI) compatibility, cell compatibility, blood compatibility, osteogenesis, and bioactivity.
View Article and Find Full Text PDFMaterials (Basel)
October 2024
Mechanical Engineering Department, College of Engineering at Wadi Addawaser, Prince Sattam bin Abdulaziz University, Wadi Addawaser 18734, Saudi Arabia.
The influence of equal channel angular pressing (ECAP) and cyclic extrusion compression (CEC) of Al-1080 on the pressing load, microstructure, and tensile properties was investigated. The pressing peak loads of the CEC were 218.8-265.
View Article and Find Full Text PDFMaterials (Basel)
October 2024
Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, China.
Acta Biomater
November 2024
Graduate School of Peking Union Medical College, Beijing 100730, China; School of Materials Science and Engineering, Peking University, Beijing 100871, China. Electronic address:
Copper-containing intrauterine devices (Cu-IUD) are adopted by worldwide women for contraception with the advantages of long-term effectiveness, reversibility and affordability. However, adverse effects occur in the initial implantation stage of Cu-IUD in uterine because of the burst release of Cu. To minimize the burst release, in this study, we designed a series of Cu-Fe alloys with 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!