A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In vitro and in vivo degradation behavior and the long-term performance of biodegradable PLCL balloon implants. | LitMetric

In vitro and in vivo degradation behavior and the long-term performance of biodegradable PLCL balloon implants.

Int J Pharm

Institute of Drug Research, School of Pharmacy-Faculty of Medicine, The Hebrew University of Jerusalem, Jerusalem 91120, Israel. Electronic address:

Published: January 2020

Biodegradable poly(l-lactide-co-ε-caprolactone) (PLCL) are used to prepare inflatable balloon implants in treating rotator-cuff injuries and tissue separation. These balloon implants act as a temporary spacer for tissues, while reducing pain and allowing rehabilitation after surgery. It is essential to ensure that each balloon fulfill two requirements after implantation: (1) display a well-defined degradation profile, and (2) remain unaffected by premature rapture or leakage. Storage also affects the stability of a polymer-based implant. Since the balloons are implanted into humans, it is essential to understand their in vitro and in vivo degradation along with their physicochemical properties. It is unpredictable if balloon storage on their performance. Therefore, the in vitro and in vivo degradation behavior of PLCL balloons was examined during one year, and the information obtained was used to correlate reliability under prolonged storage conditions. We investigated changes in weight, melting temperature (T), molecular weight distribution (M, M and PDI), crystallinity (Χ), optical activity [α], and inherent viscosity (η) of the balloons during the entire degradation time. We also examined the molecular properties of the balloons under annealing and extreme temperature conditions, such as the combined effect of temperature and humidity that simulate various storage conditions. We have concluded that degradation of the PLCL balloons is slow, and they remain stable during the test period. Results reveal that the balloons retain their molecular properties under long-term storage, annealing, and extreme temperature conditions. The balloons did not show any variation from reference samples, and they exhibited a constant stability profile even after shelf-storage of more than 3 years. These findings can serve as a case study for evaluating various other biodegradable materials.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijpharm.2019.118870DOI Listing

Publication Analysis

Top Keywords

vitro vivo
12
vivo degradation
12
balloon implants
12
degradation behavior
8
plcl balloons
8
storage conditions
8
molecular properties
8
annealing extreme
8
extreme temperature
8
temperature conditions
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!