A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dye-Modified Metal-Organic Framework as a Recyclable Luminescent Sensor for Nicotine Determination in Urine Solution and Living Cell. | LitMetric

A water-stable and pH-independent sensor for qualitative and quantitative detection of nicotine in urine solution and living cell was successfully developed. This material, named MB@UiO-66-NH, can be synthesized by encapsulating methylene blue (MB) with a well-known metal-organic framework (MOF) UiO-66-NH through a simple impregnation method. The fluorescence intensity of the system was significantly enhanced when a certain amount of nicotine was added. In the meanwhile, MB is reduced by reductive nicotine to form leucomethylene blue (LB). The proposed sensor displayed excellent selectivity and sensitivity toward nicotine with limit of detection (LOD) of 0.98 μM, which is comparable or even better than that of the electrochemistry detecting methods for nicotine. The obvious enhancement and blue shift of the emission arise from the photoinduced electron transfer (PET) from LB to the UiO-66-NH. The photophysical properties and the sensing applications of MB@UiO-66-NH suggest that this composite can be acted as a sensitive, selective, recyclable, and fluorogenic sensor for nicotine determination in urine solution and living cell.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.9b17310DOI Listing

Publication Analysis

Top Keywords

urine solution
12
solution living
12
living cell
12
metal-organic framework
8
sensor nicotine
8
nicotine determination
8
determination urine
8
nicotine
7
dye-modified metal-organic
4
framework recyclable
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!