A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Mechanical, antibacterial, and biocompatibility mechanism of PVD grown silver-tantalum-oxide-based nanostructured thin film on stainless steel 316L for surgical applications. | LitMetric

Mechanical, antibacterial, and biocompatibility mechanism of PVD grown silver-tantalum-oxide-based nanostructured thin film on stainless steel 316L for surgical applications.

Mater Sci Eng C Mater Biol Appl

Tissue Engineering Group (TEG), Department of Orthopaedic Surgery (NOCERAL), Faculty of Medicine, University of Malaya, 50603, Kuala Lumpur, Malaysia.

Published: February 2020

Surgical site infection associated with surgical instruments has always been a factor in delaying post-operative recovery of patients. The evolution in surface modification of surgical instruments can be a potential choice to overcome the nosocomial infection mainly caused by bacterial populations such as Staphylococcus aureus, Pseudomonas aeruginosa, and Escherichia coli. A study was, therefore, conducted characterising the morphology, hydrophobicity, adhesion strength, phase, Nano-hardness, surface chemistry, antimicrobial and biocompatibility of SS 316L steel deposited with a Nano-composite layer of Silver (Ag) and Tantalum oxide (TaO) using physical vapour deposition magnetron sputtering. The adhesion strength of Ag/AgTaO coating on SS 316L and treated at 250-850 °C of thermal treatment was evaluated using micro-scratch. The Ag/Ag-TaO-400 °C was shown a 154% improvement in adhesion strength on SS 316L when compared with as-sputtered layer or Ag/Ag-TaO-250, 550, 700 and 850 °C. The FESEM, XPS, and XRD indicated the segregation of Ag on the surface of SS 316L after the crystallization. Wettability and Nano-indentation tests demonstrated an increase in hydrophobicity (77.3 ± 0.3°) and Nano-hardness (1.12 ± 0.43 GPa) when compared with as-sputtered layer, after the 400 °C of thermal treatment. The antibacterial performance on Ag/Ag-TaO-400 °C indicated a significant zone of inhibition to Staphylococcus aureus (A-axis: 16.33 ± 0.58 mm; B-axis: 25.67 ± 0.58 mm, p < 0.01) and Escherichia coli (A-axis: 16.33 ± 1.15 mm; B-axis: 26.00 ± 0.00 mm, p < 0.01) when compared with SS 316L or Ag/Ag-TaO-700 °C, which showed no inhibition. The biocompatibility tests on Ag/Ag-TaO-400 °C demonstrated an excellent in cell attachment, F-actin protein expression and proliferation/viability of bone marrow derived mesenchymal stromal on day 14 when compared with uncoated or Ag/Ag-TaO-700 °C. This study shows that the Ag segregation process, hydrophobicity, adhesion strength, crystallization, and hardness progressively improved after the annealing up to 400 °C.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.msec.2019.110304DOI Listing

Publication Analysis

Top Keywords

adhesion strength
12
surgical instruments
8
staphylococcus aureus
8
thermal treatment
8
compared as-sputtered
8
as-sputtered layer
8
316l
5
mechanical antibacterial
4
antibacterial biocompatibility
4
biocompatibility mechanism
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!