A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The sacral screw placement depending on morphological and anatomical peculiarities. | LitMetric

Purpose: Various pathologies of the lumbosacral junction require fusion of the L5/S1 segment. However, pseudarthroses, which often come along with sacral screw loosening, are problematic. The aim of the present investigation was to elaborate the morphological features of the L5/S1 segment to define a so-called "safe zone" for bi- or tricortical screw placement without risking a damage of the iliac vessels.

Methods: A total of one hundred computed tomographies of the pelvis were included in this investigation. On axial and sagittal slices, pedicle morphologies, the prevertebral position of the iliac vessels, the spinal canal and the area with the largest bone density were analyzed.

Results: Beginning from the entry point of S1-srews iliac vessels were located at an average angle of 7° convergence, the spinal canal at 38°. Bone density was significantly higher centrally with a mean value of 276 Hounsfield Units compared to the area of the Ala ossis sacri. The largest intraosseous screw length could be achieved at an angle of 25°. The average pedicle width was 20 mm and the pedicle height 13 mm.

Conclusions: A "safe-zone" for bicortical screw placement at S1 with regard to the course of the iliac vessels could be defined between 7° and 38° convergence. Regarding the area offering the largest bone density and the maximal possible screw length, a convergence of 25° is recommended at S1 to reduce the incidence of screw loosening. Screw diameter, as a further influence factor on screw holding, is limited by pedicle height not pedicle width.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00276-019-02373-xDOI Listing

Publication Analysis

Top Keywords

screw placement
12
iliac vessels
12
bone density
12
sacral screw
8
l5/s1 segment
8
screw
8
screw loosening
8
spinal canal
8
largest bone
8
screw length
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!