A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Less than one minute low-pressure gas chromatography - mass spectrometry. | LitMetric

Less than one minute low-pressure gas chromatography - mass spectrometry.

J Chromatogr A

School of Chemistry, Tel Aviv University, Tel Aviv 69978, Israel; Aviv Analytical Ltd., 24 Hanagar Street, Hod Hasharon 4527713, Israel. Electronic address:

Published: February 2020

Conventional gas chromatography - mass spectrometry (GC-MS) takes 20-40 min per sample, which is undesirably slow in any application if speed can be increased while still meeting analytical needs. In this study, we achieved reasonably good separations with full analysis cycle times of less than 1 min by combining for the first time low-pressure (LP) GC-MS with low thermal mass (LTM) resistive-heating for rapid temperature ramping and cooling of the capillary column. The analytical column is threaded into the LTM thin-walled metal tubing in an instrumental device known as "LTM Fast GC" that is mounted at the top of the gas chromatograph in a detector port. The column inlet and outlet are connected to the GC injector and MS transfer line as usual. For LPGC-MS, a 40 cm, 0.1 mm. i.d. uncoated flow restrictor capillary connected at the injector is coupled with a 2.6 m, 0.25 mm i.d., 0.25 µm film thickness analytical column leading to the MS. Thus, the inlet operates at normal GC pressures, but the analytical column is under vacuum, which increases the optimal helium carrier gas flow velocity thereby increasing speed of full range separations while maintaining acceptable quality of chromatography. This column configuration in LTM-LPGC-MS trades a 64-fold gain in speed of analysis vs. standard GC-MS for a 4-fold loss in chromatographic peak capacity, thereby converting analysis time from minutes into seconds in common applications. For example, jet fuel containing fatty acid methyl esters (akin to biofuel) was separated in 25 s with <1 min full analysis cycle time. An EPA Method 8270 mixture of 76 analytes was also analyzed in <1 min full cycle time by LTM-LPGC-MS. Other examples include very fast analysis of heroin in a street drug powder and elucidation of a new organic synthetic compound. In this report, we describe and discuss the several advantageous and practical features of LTM-LPGC-MS, as well as its trade-offs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2019.460691DOI Listing

Publication Analysis

Top Keywords

analytical column
12
gas chromatography
8
chromatography mass
8
mass spectrometry
8
connected injector
8
column
6
minute low-pressure
4
gas
4
low-pressure gas
4
spectrometry conventional
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!