Unlabelled: The use of hexapod circular external fixation in acute tibia fracture care is increasing as more general orthopaedic surgeons are gaining expertise with the use of this treatment modality. Limited data is currently available on the complications that may be encountered with this treatment strategy.
Aim: To review the complications and outcomes of acute diaphyseal tibia fractures definitively treated with hexapod circular external fixation at a high volume orthopaedic trauma centre.
Methods: Retrospective review of clinical and radiological data of adult patients with acute diaphyseal tibia fractures treated with hexapod external fixation between 2012 and 2015 at a single centre.
Results: A total of 102 diaphyseal fractures were definitively treated with hexapod circular external fixation. Union was achieved in 101 cases with an average time to union of 25.6 weeks. Complications included pin site infection (56%); wound complications (19.67%); osteitis (11.76%); malunion (15.69%) and knee and ankle joint contractures (31.32%).
Conclusion: Hexapod circular external fixation as definitive treatment of for diaphyseal tibia fractures demonstrates an excellent union rate with acceptable time to union. Complications rates are comparable to that of all fine wire circular fixators. Malalignment in is however a concern, considering that this device enables the surgeon to achieve accurate alignment through gradual deformity correction aided by computer software.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.injury.2019.11.012 | DOI Listing |
J Clin Med
January 2025
Department of Biochemistry and Biotechnology, Institute of Biological Sciences, Maria Curie-Sklodowska University, 20-614 Lublin, Poland.
Limb lengthening and deformity correction techniques, particularly distraction osteogenesis, have significantly evolved in pediatric orthopedics. This study examines the temporal changes of key biochemical markers-vascular endothelial growth factor (VEGF), fibroblast growth factor 1 (FGF-1), and the propeptide of type I collagen (P1NP)-during the limb lengthening process. Twenty pediatric patients (aged 13-16) underwent distraction osteogenesis using the Circular Hexapod External Fixator.
View Article and Find Full Text PDFJ Am Acad Orthop Surg Glob Res Rev
December 2024
From Limb Lengtheneing and Complex Reconstruction Service, Khoula Hospital, Ministry of Health, Muscat, Oman; and the Department of Orthopaedic Surgery, Kasr Al-Ainy School of Medicine, Cairo University, Cairo, Egypt.
Congenital hallux varus is an unusual condition in which the big toe is medially angulated at the metatarsophalangeal joint. Different surgical methods have been described to correct it; however, there is always a risk of recurrence. The multiplanar nature of the deformity and the disrupted anatomy from a previous surgery make recurrent cases difficult to treat.
View Article and Find Full Text PDFBMC Musculoskelet Disord
November 2024
Department of Orthopaedics and Traumatology, University of Health Sciences Şişli Hamidiye Etfal Education and Research Hospital, Istanbul, Turkey.
Background: With the assistance of smart fixator technologies, the correction of complex deformities has been facilitated; however, the accurate integration of specialized radiographs and measurements into the system remains the greatest disadvantage, necessitating specialized imaging and an experienced team. When inexperienced technicians and doctors perform these specialized postoperative radiographs, excessive exposure of the patient and team to radioactive rays exacerbates inadequacies in measurements and delays the correction of residual deformities due to angular and translational adjustments. In this study, we compared postoperative measurements with those taken peroperatively via fluoroscopy, hypothesizing that it reduces the exposure of the patient and team to radioactive rays, allows for more accurate and timely correction of deformities and assembly parameters, and reduces time and costs.
View Article and Find Full Text PDFMitochondrial DNA B Resour
October 2024
Department of Life Sciences, University of Siena, Siena, Italy.
The complete mitochondrial genome of the shining leaf chafer was sequenced and is herein described. The mitogenome consists of a circular molecule of 16,805 bp, with an overall AT content of 75.7%.
View Article and Find Full Text PDFFoot Ankle Surg
February 2025
Limb Reconstruction Unit, Department of Orthopaedic Surgery and Traumatology, Hospital Universitario Doce de Octubre, Madrid, Spain. Electronic address:
Introduction: Foot and ankle pathology can often require complex surgical reconstruction. Until recently, circular external fixators such as the Ilizarov frame have proven to be useful, yet they fall short when progressive, precise corrections are required. Computer-assisted hexapod external fixators seek to address many of the shortfalls of traditional circular fixators.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!