A fast MOSFET rf switch for low-field NMR and MRI.

J Magn Reson

Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB R3T 2N2, Canada; Department of Physics, University of Winnipeg, Winnipeg, MB R3B 2E9, Canada. Electronic address:

Published: January 2020

TRansmit Array Spatial Encoding (TRASE) MRI uses trains of rf pulses alternately produced by distinct transmit coils. Commonly used coil switching involving PIN diodes is too slow for low- and ultra-low-field MRI and would introduce wait times between pulses typically as long as each individual pulse in a few mT. A MOSFET-based rf switch is described and characterised. Up to hundreds of kHz, it allows for sub-μs switching of rf currents from a single amplifier to several coils with sufficient isolation ratio and negligible delay between pulses. Additionally, current switching at null current and maximum voltage can be used to abruptly stop or start pulses in series-tuned rf coils, therefore avoiding the rise and fall times associated with the Q-factors. RF energy can be efficiently stored in tuning capacitors for times as long as several seconds. Besides TRASE MRI, this energy storage approach may find applications in fast repeated spin-echo experiments. Here, a threefold acceleration of TRASE phase-encoding is demonstrated when MOSFET switches are used instead of fast reed relays.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmr.2019.106638DOI Listing

Publication Analysis

Top Keywords

trase mri
8
fast mosfet
4
mosfet switch
4
switch low-field
4
low-field nmr
4
mri
4
nmr mri
4
mri transmit
4
transmit array
4
array spatial
4

Similar Publications

Transmit array spatial encoding (TRASE) is an MR imaging technique that achieves k-space encoding through the use of phase gradients in the RF transmit field. Without requiring B gradient fields, TRASE MRI can be performed using significantly cheaper bi-planar permanent magnets or Halbach arrays. For TRASE encoding with these magnets, the twisted solenoid has been demonstrated as the most efficient RF transmit coil; however, this specific geometry results in a long coil with a relatively short imaging volume.

View Article and Find Full Text PDF

Generating accurate tip angles for NMR outside the rotating-wave approximation.

J Magn Reson

December 2022

Laboratoire Kastler Brossel, ENS-Université PSL, CNRS, Sorbonne Université, Collège de France, 24 rue Lhomond, 75005 Paris, France. Electronic address:

The generation of accurate tip angles is critical for many applications of nuclear magnetic resonance. In low static field, with a linear rather than circular polarized rf field, the rotating-wave approximation may no longer hold and significant deviations from expected trajectories on the Bloch sphere can occur. For rectangular rf pulses, the effects depend strongly on the phase of the rf field and can be further compounded by transients at the start and end of the pulse.

View Article and Find Full Text PDF

Concept for gradient-free MRI on twin natural slices.

MAGMA

August 2023

Division of Biomedical Engineering and the quanTA Centre, University of Saskatchewan, Saskatoon, Saskatchewan, Canada.

Objective: The design of an MRI for use in space requires that the hardware be kept to an absolute minimum in terms of mass, complexity, and power. In addition, NASA requirements are that the external stray field needs to be less than 3.2 Gauss, 7 cm from the MRI enclosure.

View Article and Find Full Text PDF

The effects of coupled B fields in B encoded TRASE MRI - A simulation study.

Magn Reson Imaging

December 2020

Space MRI Lab, Division of Biomedical Engineering, University of Saskatchewan, Saskatoon, Canada. Electronic address:

Transmit Array Spatial Encoding (TRASE) is a novel MRI technique that encodes spatial information by introducing phase gradients in the transmit RF (B) magnetic field. Since TRASE relies on the use of multiple RF fields (B fields with different phase gradients) for k-space traversal, a TRASE pulse sequence requires RF pulses that are produced by switching between the transmit coils (B fields). However, interactions among the transmit RF coils can cause un-driven coils to produce unwanted B fields that impair the spatial encoding.

View Article and Find Full Text PDF

A fast MOSFET rf switch for low-field NMR and MRI.

J Magn Reson

January 2020

Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB R3T 2N2, Canada; Department of Physics, University of Winnipeg, Winnipeg, MB R3B 2E9, Canada. Electronic address:

TRansmit Array Spatial Encoding (TRASE) MRI uses trains of rf pulses alternately produced by distinct transmit coils. Commonly used coil switching involving PIN diodes is too slow for low- and ultra-low-field MRI and would introduce wait times between pulses typically as long as each individual pulse in a few mT. A MOSFET-based rf switch is described and characterised.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!