A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A New Principle for Measuring the Average Relative Humidity in Large Volumes of Non-Homogenous Gas. | LitMetric

Due to the current extent of arid regions, the pressure on available water resources is increasing. A suitable measure for water availability and dynamics in dry soil is the relative humidity of the soil air. Due to the heterogeneity of soil, water inputs, and root water uptake, the humidity of soil air will vary in space. Therefore, area-representative measurement methods are needed to find a representative measure of the soil water status. Existing sensors for the direct determination of relative humidity only represent a single location with a spatial extent of up to several cm. We introduce a new measuring principle that averages over a spatially heterogeneously distributed relative humidity. It is based on the selective diffusion of water vapor pressure through a tubular semipermeable membrane to/from a closed measurement chamber. A measured pressure change is sensitive to the water vapor pressure and enables, without any external calibration, to estimate an average of the relative humidity. The comparison of our first laboratory prototype of the new sensor with calibrated reference sensors for relative humidity in a range of approx. 4 to 100% proves the linearity of the measuring method and its high accuracy. For further optimization improved reference measurement techniques are necessary. A potential application is the improvement of water use efficiency in irrigated agriculture.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6928645PMC
http://dx.doi.org/10.3390/s19235073DOI Listing

Publication Analysis

Top Keywords

relative humidity
24
average relative
8
water
8
humidity soil
8
soil air
8
soil water
8
water vapor
8
vapor pressure
8
humidity
7
relative
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!