A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Instrumented surgical treatment for metastatic spinal tumors: is fusion necessary? | LitMetric

Objective: The goal of this study was to evaluate the radiographic and clinical results of instrumentation surgery without fusion for metastases to the spine.

Methods: Between 2010 and 2017, patients with spinal tumors who underwent instrumentation without fusion surgery were consecutively evaluated. Preoperative and postoperative clinical data were evaluated. Data were inclusive for last follow-up and just prior to death if the patient died. Instrumentation-related complications included screw migration, screw or rod breakage, cage migration, and screw loosening.

Results: Excluding patients who died within 6 months, a total of 136 patients (140 operations) were recruited. The average follow-up duration was 16.5 months (median 12.4 months). The pain visual analog scale score decreased from 6.4 to 2.5 (p < 0.001) and the Eastern Cooperative Oncology Group scale score improved (p < 0.001). There were only 3 cases (2.1%) of symptomatic instrumentation-related complications that resulted in revisions. There were 6 cases of nonsymptomatic complications. The most common complication was screw migration or pull-out (5 cases). There were 3 cases of screw or rod breakage and 1 case of cage migration. Two-thirds of the cases of instrumentation-related complications occurred after 6 months, with a mean postoperative period of 1 year.

Conclusions: The current study reported successful outcomes with very low complication rates after nonfusion surgery for patients with spinal metastases, even among those who survived for more than 6 months. More than half of the instrumentation-related complications were asymptomatic and did not require revision. The results suggest that nonfusion surgery might be sufficient for a majority of patients with spinal metastases.

Download full-text PDF

Source
http://dx.doi.org/10.3171/2019.8.SPINE19583DOI Listing

Publication Analysis

Top Keywords

instrumentation-related complications
16
patients spinal
12
spinal tumors
8
screw migration
8
migration screw
8
screw rod
8
rod breakage
8
cage migration
8
scale score
8
nonfusion surgery
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!