Background: To assess the long-term safety and effectiveness of endovascular aneurysm repair (EVAR) treatment with unibody endograft deployed on aortic bifurcation (anatomical fixation).

Methods: A retrospective, observational, single-center study of patients treated from 1999 to 2002 with unibody bifurcated endograft. Follow-up protocol required clinical and doppler-ultrasound at 1 and 6 months and annually thereafter, computed tomography angiography at 1-, 6- and 12-months and then every year. Primary endpoints included technical and treatment success, survival and freedom from late EVAR failure; secondary endpoints were freedom from late open conversion (LOC), freedom from late re-interventions and endoleaks.

Results: Seventy-three patients, mean age of 73±6 years were enrolled. Median follow-up was 6±0.5 years. Technical success was 98.6% (N.=71/73; causes of failure: 1 open conversion and 1 type Ib endoleak). A treatment success of 96% (N.=69/72) was recorded due to endoleaks (N.=2; 1 type Ia and 1 type Ib) and limb occlusion (N.=1). Survival at 1, 5, 10, 15 and 18 years was 90%, 58%, 40%, 32% and 23% respectively. One aneurysm-related death for infection of the endograft was registered. EVAR failure was 14% (N.=10/71). Three LOC were recorded and freedom from reinterventions at 1, 5, 10 and 18 years was 99%, 91%, 86% and 86%. Fourteen endoleaks were recorded: Ia (N.=6; 42.8%), Ia+Ib (N.=1; 7.1%), Ib (N.=2; 14.2%) and II (N.=5; 35.6%). Four endoleaks were observed, 9 endovascular correction and 1 LOC were required. Endoleaks free survival of 90% at 1-year and 75% at the end of the study. Aneurysm sac shrinkage was observed in 79% (N.=56/71).

Conclusions: This small, retrospective cohort of anatomically fixed EVAR demonstrated long-term safety and effectiveness. The design of the unibody graft did not substantially change and newer generation should guarantee the same performance.

Download full-text PDF

Source
http://dx.doi.org/10.23736/S0021-9509.19.11076-2DOI Listing

Publication Analysis

Top Keywords

freedom late
12
endovascular aneurysm
8
aneurysm repair
8
unibody endograft
8
long-term safety
8
safety effectiveness
8
treatment success
8
evar failure
8
open conversion
8
twenty years
4

Similar Publications

Reconstruction of reverberant sound fields over large spatial domains.

J Acoust Soc Am

January 2025

Acoustic Technology, Department of Electrical & Photonics Engineering, Technical University of Denmark, Kongens Lyngby, Denmark.

Characterising acoustic fields in rooms is challenging due to the complexity of data acquisition. Sound field reconstruction methods aim at predicting the acoustic quantities at positions where no data are available, incorporating generalisable physical priors of the sound in a room. This study introduces a model that exploits the general time structure of the room impulse response, where a wave-based expansion addresses the direct sound and early reflections, localising their apparent origin, and kernel methods are applied to the late part.

View Article and Find Full Text PDF

Mid-term outcomes of frozen elephant trunk for chronic aortic dissection.

Can J Cardiol

January 2025

Cardiovascular department, Cardiology Research Institute, Tomsk National Research Medical Centre, Russian Academy of Sciences, Tomsk, Russian Federation.

Background: The aim of the study was to analyze the mid-term outcomes of the frozen elephant trunk (FET) procedure for chronic aortic dissection (СAD).

Methods: From March 2012 to December 2022, 123 FET procedures were performed in patients with acute and chronic aortic dissection as well as aortic aneurysm. Fifty-five patients with chronic aortic dissection (CAD) were eligible for study.

View Article and Find Full Text PDF

Background: The expanded polytetrafluoroethylene (ePTFE) valved conduit (VC) has been reported for pulmonary valve replacement (PVR). The purpose of this study was to review long-term outcomes of our trileaflet ePTFE VC.

Methods: This multicenter study was performed with institutional review board approval from each institution.

View Article and Find Full Text PDF

Background: Comparative studies of outcomes between different biological mitral valve prostheses are scarce. This study compares the late clinical results of valve replacement with the Epic and Mosaic bioprostheses.

Methods: Patients undergoing isolated elective mitral valve replacement (MVR) between 2005 and 2019 were eligible for inclusion.

View Article and Find Full Text PDF

Aims: As patients experience longer survival on HeartMate 3 left ventricular assist devices, there is a need to characterize long-term risks of adverse outcomes more precisely. This study characterized temporal variations in risks of mortality and adverse outcomes in patients with a HeartMate 3.

Methods And Results: From October 2015 to January 2023, 431 HeartMate 3 devices were implanted at Cleveland Clinic.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!