Precise fitting and immobilisation of bone transplants at the recipient site is of utmost importance for the healing process. With the help of the standardised Osseo Transfer System, the recipient site is adjusted to the graft, rather than vice versa as it is typically done. The aim of this study was to analyse donor-site morbidity after harvesting cylindrical bone grafts from the retromolar region using the Osseo Transfer System. The patient satisfaction with the surgical procedures was also evaluated. All patients treated with this standardised reconstruction method between 2006 and 2013 at the Department of Cranio-Maxillofacial Surgery, University Hospital Giessen, were included in this study. Complications were recorded and evaluated. Bone graft success and patient satisfaction were documented with a questionnaire, and then confirmed by clinical and radiological follow-up examinations. Fifty-four patients were treated and 64 harvested cylindrical autologous bone grafts were transplanted. In all cases, dental implants could be inserted after bone healing. One patient lost an implant, associated with failure of the bone graft. Six patients who were examined continued to show neurological disorders in locally limited areas. No complete or long-term damage of the inferior alveolar nerve occurred. More than 94% (n = 52) of the patients were 'very satisfied' or 'satisfied' with the results and would recommend this surgical treatment to other patients. The standardised Osseo Transfer was an effective treatment option for small and mid-sized alveolar ridge augmentations. A low donor-site morbidity rate and a high transplant success rate were verified. The Osseo Transfer System demonstrated to be a reliable surgical technique without major complications. We highly recommend this surgical augmentation procedure as a surgical treatment for local bone defects.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6887743PMC
http://dx.doi.org/10.3390/ma12223802DOI Listing

Publication Analysis

Top Keywords

osseo transfer
16
donor-site morbidity
12
transfer system
12
bone
8
recipient site
8
standardised osseo
8
bone grafts
8
patient satisfaction
8
patients treated
8
bone graft
8

Similar Publications

The complexity of the osseo-ligamentous lumbopelvic system has made it difficult to perform both, the overall preparation as well as specimen harvesting and material testing with a reasonable amount of time and personnel. The logistics of such studies present a hurdle for reproducibility. A structured procedure was developed and proved, which allows all necessary steps to be carried out reproducibly and in a reasonable time.

View Article and Find Full Text PDF

Precise fitting and immobilisation of bone transplants at the recipient site is of utmost importance for the healing process. With the help of the standardised Osseo Transfer System, the recipient site is adjusted to the graft, rather than vice versa as it is typically done. The aim of this study was to analyse donor-site morbidity after harvesting cylindrical bone grafts from the retromolar region using the Osseo Transfer System.

View Article and Find Full Text PDF

Brachymetatarsia: One-stage Versus Two-Stage Procedures.

Foot Ankle Clin

December 2019

CALO - Centro de Alongamento Ósseo, Rio de Janeiro, Brazil.

Brachymetatarsia is a rare deformity with controversial clinical presentation. Multiple acute and gradual lengthening surgical techniques have been described for correction of this type of foot deformity. All techniques try to create a better appearance, facilitate shoeing, or solve possible transfer metatarsalgia.

View Article and Find Full Text PDF

Detection of cAMP and of PKA activity in Saccharomyces cerevisiae single cells using Fluorescence Resonance Energy Transfer (FRET) probes.

Biochem Biophys Res Commun

June 2017

Department of Biotechnology and Biosciences, University of Milano-Bicocca, Milan, Italy; SysBio Centre of Systems Biology, Piazza della Scienza 2, I-20126 Milan, Italy. Electronic address:

In Saccharomyces cerevisiae the second messenger cyclic adenosine monophosphate (cAMP) and protein kinase A (PKA) play a central role in metabolism regulation, stress resistance and cell cycle progression. To monitor cAMP levels and PKA activity in vivo in single S. cerevisiae cells, we expressed an Epac-based FRET probe and a FRET-based A-kinase activity reporter, which were proven to be useful live-cell biosensors for cAMP levels and PKA activity in mammalian cells.

View Article and Find Full Text PDF

Many patents have been devoted to developing medical nanometer zirconia ceramic grinding techniques that can significantly improve both workpiece surface integrity and grinding quality. Among these patents is a process for preparing ceramic dental implants with a surface for improving osseo-integration by sand abrasive finishing under a jet pressure of 1.5 bar to 8.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!