Introduction: Inhaled flecainide significantly alters atrial electrical properties with the potential to terminate atrial fibrillation (AF) efficiently by optimizing dose and drug formulation.
Methods: Seventeen Yorkshire pigs were studied. Intrapericardial acetylcholine and burst pacing were used to induce AF. Effects of a novel cyclodextrin formulation (hydroxypropyl-ß-cyclodextrin [HPßCD]) of flecainide (75 mg/mL, 0.5 or 1.0 mg/kg, bolus) instilled intratracheally at 2 minutes after AF initiation were studied. Concentration time-area analyses of flecainide HPßCD were compared to the traditional acetate formulation.
Results: Intratracheal instillation of flecainide HPßCD accelerated the conversion of AF to sinus rhythm in a dose-proportional manner, shortening AF duration by 47% (P = .014) and 79% (P = .002) at the lower and higher doses, respectively, compared to intratracheal sterile water placebo. AF dominant frequency was reduced by 11% (P = .04) and 29% (P = .004) respective to dose. At 2 minutes after intratracheal flecainide HPßCD, atrial depolarization (P ) duration increased by 12% (P = .02) and 17% (P = .009) at the lower and higher doses, respectively. At this time, the PR interval was prolonged by 9% (P = .04 for the higher dose) and AV node conduction was slowed, decreasing the ventricular rate during AF by 16% (P = .002) and 28% (P = .007) for the lower and higher doses. Flecainide HPßCD achieved the more efficient conversion of AF than the acetate formulation, reflected in a markedly reduced area under the curve (P = .04).
Conclusion: Intratracheal instillation of the new flecainide HPßCD formulation effectively terminates AF through efficient multimodal actions including slowing of atrial conduction velocity and decreasing AF dominant frequency, allowing reduced net drug delivery and inhalation time.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/jce.14289 | DOI Listing |