Umbilical artery base deficit/excess: sailing blindly in a thick fog.

J Matern Fetal Neonatal Med

The Ottawa Hospital-General Campus, University of Ottawa, Ottawa, Canada.

Published: December 2021

Assessing the wellbeing of newborns at birth with base deficit (BD)/base excess(BE) is well anchored in clinicians' practice. However, clinicians may not fully understand the concepts behind BD and the concerns regarding the validity of BD results provided by the hospital laboratory. These concerns are linked to the inconsistencies between the equations to calculate BD, and that these equations do not consider the aspects of acid-base physiology at birth. Additionally, the evidence-based supporting BD threshold in the literature to help physicians in making decisions is rather insufficient. These considerations support the need to review practice guidelines that use BD to guide decisions and bring to an end to clinicians to sail blindly in a thick fog.

Download full-text PDF

Source
http://dx.doi.org/10.1080/14767058.2019.1685966DOI Listing

Publication Analysis

Top Keywords

blindly thick
8
thick fog
8
umbilical artery
4
artery base
4
base deficit/excess
4
deficit/excess sailing
4
sailing blindly
4
fog assessing
4
assessing wellbeing
4
wellbeing newborns
4

Similar Publications

Background: Wound healing is a complex process influenced by a variety of environmental factors. Dressing materials play a critical role in creating barriers against contaminants, maintaining optimal moisture levels, and absorbing wound exudate. Therefore, selecting materials tailored to wound characteristics is crucial for enhancing outcomes.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to assess how reliable ultrasound is in locating the central slip of the extensor digitorum tendon (CSET) and to compare its measurements with traditional anatomical methods.
  • Four rheumatologists independently measured the thickness of the CSET in cadaver fingers and evaluated the effects of creating artificial synovitis on their measurements.
  • Results showed that ultrasound measurements were highly reliable and closely matched anatomical measurements, indicating it can effectively identify CSET without interference from joint conditions like synovitis.
View Article and Find Full Text PDF

Reliability of Intestinal Ultrasound for Evaluating Crohn's Disease Activity Using Point-of-care and Central Reading.

Clin Gastroenterol Hepatol

August 2024

IBD Service, Department of Gastroenterology, The Queen Elizabeth Hospital, Adelaide, South Australia, Australia; Faculty of Health Sciences, School of Medicine, University of Adelaide, Adelaide, South Australia, Australia. Electronic address:

Background & Aims: Intestinal ultrasound (IUS) is increasingly used to assess Crohn's disease (CD) activity in clinical practice. However, application in clinical trials has been limited by heterogeneous scoring methods and concerns about reliability. We aimed to determine the inter- and intra-rater reliability of locally and centrally read IUS parameters for evaluating CD using prospectively performed scans.

View Article and Find Full Text PDF

Introduction: Skin metastases arise in 10% of cancer patients, but standardized dermoscopy diagnostic criteria for skin metastases remain poor. This study's objective was to analyze the dermoscopy features of skin metastases from advanced systemic and cutaneous cancers.

Methods: A retrospective study on 715 dermoscopy images of skin metastases from 33 patients with various primary cancers (breast, ovary, melanoma, non-melanoma skin cancer, and chronic leukemia) attending two academic centers between 2013 and 2023 was performed.

View Article and Find Full Text PDF

An Explorative Anatomical Study on Inter-Individual Variation of the Tibial Nerve and Landmarks for Perineural Anesthesia in Horses.

Animals (Basel)

July 2024

Department of Large Animal Surgery, Anaesthesia and Orthopaedics, Faculty of Veterinary Medicine, Ghent University, 9820 Merelbeke, Belgium.

Perineural anesthesia of the tibial nerve can be performed ultrasound-guided or blindly, with the latter still being commonly used in equine practice due to practical constraints, despite its lower accuracy and hence, common failure to achieve desensitization. This may be associated with anatomical variations or inadequate landmarks for injection. To examine the course of the tibial nerve, document potential anatomical variations, and determine optimal landmarks for perineural injection, dissection was conducted along the medial aspect of the tibia in 10 paired cadaver hindlimbs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!