Objectives: Describe audiologic outcomes in hearing preservation cochlear implantation (CI) using a precurved electrode array inserted using an external sheath and evaluate association of electrode positioning and preservation of residual hearing.

Study Design: Retrospective review.

Setting: Tertiary otologic center.

Patients: Twenty-four adult patients who underwent hearing preservation CI with precurved electrode array.

Interventions: CI, intraoperative computed tomography (CT) OUTCOME MEASURES:: Audiologic measures (consonant-nucleus-consonant [CNC] words, AzBio sentences, low-frequency pure tone averages [LFPTA]) and electrode location (scalar location, electrode-to-modiolus distance ((Equation is included in full-text article.)), angular insertion depth).

Results: Twenty-four adults with less than 80 dB LFPTA with a precurved electrode array inserted using an external sheath; 16 underwent intraoperative CT. LFPTA was 58.5 dB HL preoperatively, with a 17.3 dB threshold shift at CI activation (p = 0.005). CNC word scores improved from 6% preoperatively to 64% at 6 months postoperatively (p < 0.0001). There was one scalar translocation and no tip fold-overs. The average angular insertion depth was 388.2 degrees, and the average (Equation is included in full-text article.)across all electrodes was 0.36 mm. Multivariate regression revealed a significant correlation between CNC scores at 6 months and angular insertion depth (p = 0.0122; r = 0.45, adjusted r = 0.35). Change in LFPTA was not significantly associated with angular insertion depth or (Equation is included in full-text article.).

Conclusions: A low rate of translocation allows a precurved electrode array inserted using an external sheath to maintain hearing preservation rates comparable to straight electrode arrays. With scala tympani insertion, angular insertion depth is a positive marker of improved speech performance postoperatively but may be a confounder variable based on individual cochlear size.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6910978PMC
http://dx.doi.org/10.1097/MAO.0000000000002426DOI Listing

Publication Analysis

Top Keywords

precurved electrode
16
hearing preservation
12
electrode array
12
array inserted
12
inserted external
12
external sheath
12
electrode
6
preservation outcomes
4
precurved
4
outcomes precurved
4

Similar Publications

Frequency-to-Place Mismatch and Cochlear Implant Outcomes by Electrode Type.

JAMA Otolaryngol Head Neck Surg

December 2024

Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee.

Importance: Speech recognition outcomes with a cochlear implant (CI) are highly variable. One factor suggested to correlate with CI-aided speech recognition is frequency-to-place mismatch, or the discrepancy between the natural tonotopic organization of the cochlea and the electric frequency allocation of the CI electrodes within the patient's cochlea.

Objective: To evaluate the association between frequency-to-place mismatch and speech recognition outcomes in a large cohort of postlingually deafened adult CI users, while controlling for various clinical factors known to be associated with those outcomes.

View Article and Find Full Text PDF

Impact of cochlear detailed morphology on insertion results and intracochlear trauma of a slim pre-curved electrode array: a micro-CT study.

Eur Arch Otorhinolaryngol

November 2024

ENT Institute and Department of Otolaryngology, Eye and ENT Hospital, Fudan University, Shanghai, 20031, China.

Article Synopsis
  • * Eleven temporal bone specimens were used to track different metrics like angular insertion depth and cochlear dimensions after implanting the electrode, revealing key correlations between physical cochlear characteristics and insertion results.
  • * Findings suggest that specific cochlear dimensions can predict implantation success and trauma risk, with micro-CT imaging offering valuable insights to enhance current cochlear implant technology and surgical techniques.
View Article and Find Full Text PDF

Objectives: To assess the clinical utility of spread of excitation (SOE) functions obtained via electrically evoked compound action potentials (eCAP) to 1) identify electrode array tip fold-over, 2) predict electrode placement factors confirmed via postoperative computed tomography (CT) imaging, and 3) predict postoperative speech recognition through the first year post-activation in a large clinical sample.

Study Design: Retrospective case review.

Setting: Cochlear implant (CI) program at a tertiary medical center.

View Article and Find Full Text PDF

Background: Extrusion of electrodes outside the cochlea and tip fold overs may lead to suboptimal outcomes in cochlear implant (CI) recipients. Intraoperative measures such as Trans-Impedance Matrix (TIM) measurements may enable clinicians to identify electrode malposition and direct surgeons to correctly place the electrode array during surgery.

Objectives: To assess the current literature on the effectiveness of TIM measurements in identifying extracochlear electrodes and tip fold overs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!