Transcatheter aortic valve implantation (TAVI) for aortic stenosis is becoming an appealing alternative to surgical aortic valve replacement in high-risk patients and to medical therapy for inoperable ones. Several new-generation TAVI devices have been recently introduced, but comparative analyses are lacking. We aimed to compare 1-month outcomes associated with such five leading new-generation TAVI devices exploiting data collected in the prospective observational RISPEVA (Registro Italiano GISE sull'impianto di Valvola Aortica Percutanea) Study. We queried the dataset of the ongoing RISPEVA study to retrieve baseline, procedural and 1-month outcome details of patients undergoing TAVI with Acurate, Evolut, Portico, Lotus, and Sapien3. Analysis was based on unadjusted and propensity score-adjusted methods. We included 1976 patients, 234 (11.8%) treated with Acurate, 703 (35.6%) with Evolut, 151 (7.6%) with Lotus, 347 (17.6%) with Portico, and 541 (27.4%) with Sapien3. Unadjusted analysis for baseline features highlighted several significant differences, and other discrepancies were found for procedural features. Despite these differences, device and procedural success were similarly high (ranging from 98.0% to 99.4%, p > 0.05). However, procedural valve migration appeared more common with Acurate (p = 0.007), and major bleeding with Sapien3 (p = 0.002). Unadjusted analysis for 1-month outcomes also highlighted significant differences in the composite of death, stroke, myocardial infarction, major vascular complication, major bleeding, or renal failure (favoring Portico, p < 0.001), major vascular complications (favoring Lotus, p < 0.001), renal failure (favoring Portico, p = 0.035), and permanent pacemaker implantation (favoring Acurate, p < 0.001). Propensity score-adjusted analyses showed lower rates of major adverse events with Evolut and Portico (p < 0.05), major vascular complications with Lotus and Portico (p < 0.05), renal failure with Sapien3 (p < 0.05) and permanent pacemaker implantation with Acurate (p < 0.05). In conclusion, new-generation TAVI devices have different profiles of early comparative safety and efficacy. These findings should be taken into account for individualized decision making and patient management.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6864033 | PMC |
http://dx.doi.org/10.1038/s41598-019-53081-w | DOI Listing |
J Chin Med Assoc
November 2024
Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China.
Since the first transcatheter aortic valve replacement (TAVR) was performed in China in 2010, TAVR has developed rapidly. However, the temporal trends in the 1-year prognosis after TAVR in China have not been described. This study enrolled patients treated at a high-volume Chinese TAVR center, West China Hospital, between 2015 and 2022, to analyze and characterize the temporal trends in 1-year outcomes.
View Article and Find Full Text PDFClin Appl Thromb Hemost
January 2025
Cardiovascular Research Institute, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran.
Percutaneous valve implantation or surgical replacement with mechanical or biological valves are standard therapies for severe valvular heart diseases. Prosthetic valve thrombosis, though rare, is a serious complication, particularly with mechanical prostheses. This study aimed to investigate the predictive value of platelet volume parameters, including mean platelet volume (MPV), platelet distribution width (PDW), and platelet-large cell ratio (P-LCR), for valvular thrombosis risk in patients undergoing valve replacement therapy.
View Article and Find Full Text PDFCureus
December 2024
Cardiovascular Surgery, Ayase Heart Hospital, Tokyo, JPN.
Subvalvular aortic stenosis typically manifests at a young age and rarely presents in adulthood. It may cause left ventricular outflow tract stenosis, which requires surgical treatment in severe cases. The coexistence of discrete subvalvular aortic stenosis and quadricuspid aortic valve is a highly unusual finding.
View Article and Find Full Text PDFCureus
December 2024
Family Medicine, Louisiana State University Health Sciences Center, Alexandria, USA.
The VACTERL (vertebral defects, anal atresia, cardiac defects, tracheoesophageal fistula, renal anomalies, and limb abnormalities) association represents an enigmatic syndrome requiring further study. This report describes a full-term neonate born to a multiparous woman who was found, upon further examination, to have multiple congenital abnormalities, including a bicuspid aortic valve, patent foramen ovale, tracheoesophageal fistula (TEF), asymmetric crying facies, microphallus, and a single inguinal testis. The discussion explores environmental and genetic factors that may contribute to this association, as well as similar conditions, such as CHARGE (coloboma, heart defects, choanal atresia, growth retardation, genital abnormalities, and ear abnormalities) syndrome.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
December 2024
Department of Cardiac Surgery, University of Michigan, Ann Arbor, Michigan.
The Y-incision aortic annular enlargement (AAE) has been established as a safe and effective technique for upsizing the aortic annulus by 3 to 4 valve sizes. However, concerns have been raised regarding its technical complexity during reoperations, particularly given the extensive enlargement of the aortic annulus and root. We present a case of reoperative aortic valve replacement after previous Y-incision AAE for prosthetic valve endocarditis and aortic root abscess.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!